Step Four: SETTING THE CORRECT FLOW RATE & SYSTEM CHECK
•
Your Microlene Underbench System is rated to a maximum of 4 litres
per minute. Turn on the household water. Open the Pipe (or C-Clamp)
tap by turning the outlet taps anti-clockwise. To ensure the correct flow
rate, place a bucket/container (one which you know what its capacity
is) under the Microlene bench tap and turn the tap on. Time how long
it takes to fill the bucket/container - adjust the outlet taps on the Pipe
Tap (or C-Clamp) until a flow rate of no more than 4 litres per minute is
achieved. Using this flow rate it will take 2 minutes and 30 seconds to
fill a 10 litre bucket/container, 1 minute and 15 seconds to fill a 5 litre
bucket/container or 15 seconds to fill a 1 litre bucket/container.
•
Check all connections for leaks and tighten connections where required.
•
It is recommended that water is run through the Underbench system for
10 minutes (at a maximum of 4 litres per minute) into the sink to remove
any loose carbon fibres from the purifier.
•
Your Microlene Quick Connect Underbench System is now ready for use.