13
RAIN
W
AT
ER
SUPP
LY
from discharge of rainwater pu
m
p
Power to pump vi
a
3 pin socket - plug th
e
rainwater pump in here
.
1" BSP
M
200m
m
200
m
m
TO
TO
ILETS
AND/O
R
LAUNDR
Y
(do not mix/cross-connect with mains water supply
)
* Pressure Limiting Valve
MAINS
WA
TER SUPPL
Y
3/4" BSP
M
Incoming powe
r
to RainBan
k
via 3 pin plu
g
3/4" BSP
M
Stop valv
e
200 Micron ‘Y’ Straine
r
recommended but no
t
supplied.
WHERE MAINS PRESSURE EXCEEDS 600kPa. A PLV*
MUST
BE FITTED TO INLET!
RainBank
MUST
BE INSTALLE
D
HORIZONTALLY AS ILLUSTRATED
.
Stop valve
20mm hol
e
NOTE: Australian Building Standards stipulat
e
incoming mains pressure should not exceed 500kPa.
PUMP OUTSIDE TANK
OPTION - CLOSE UP
WARNING: DO NOT FIT CHECK VALVES BETWEEN RAINBANK, PUMP AND
TANK, UNLESS PUMP IS ABOVE MAXIMUM WATER LEVEL OF TANK.
IMPORTANT: ALL PIPEWORK AND OUTLET FITTINGS FROM RAINBANK MUST BE LABELLED
TO AS/NZS 3500.1. TANK MUST HAVE ISOLATION VALVE FITTED. DO NOT CONNECT WITH
CRIMPED FITTINGS.