2

3

The plug end of the level switch connects into the base of the RainBank in the 

2.5mm Miniature Audio DC power socket adjacent to incoming power lead.

The level switch itself is designed to allow for installation into the tank wall from 

the outside, with no need to gain internal access.

The level switch is 

suitable for installation 

in polyethylene, steel 

and fibreglass tanks.  

Installation in steel tanks 

may require extra care to 

ensure swarf and debris 

do not damage the tank 

coating.  If installing the 

device in a corrugated 

steel tank, you should 

ensure it is installed on 

the flat section between 

the radii, as illustrated 

below.

The level switch should 

be installed at least 

40mm above the height 

of the tank outlet.  It 

should also be placed 

away from the rainwater 

entry into the tank, so that 

the incoming flow during 

rainfall periods does not 

cause interference with 

the level switch.

The level switch can be inserted via a circular hole of 22mm diameter.  The use 

of a hole saw is recommended for this task.  Ensure all swarf is removed from the 

hole, including the internal surface of the tank.

Ensure the compression nut is loosened, so that the sealing grommet is not 

expanded.  Remove the sealing nut and insert the level switch into the hole (as 

shown below).

STEP 2

Insert Float

Ensure the level switch is correctly orientated, and the word ‘UP’ is seen on top at 

the very end of the switch body.  Now tighten the compression nut to expand the 

seal inside the tank (as shown below).

STEP 3 - Tighten

Compression Nut

Ensure the level switch is still correctly orientated, and the word ‘UP’ is seen on 

top at the very end of the switch body. 

While maintaining the orientation of the switch, screw on and tighten the sealing 

nut to finish the installation of the float switch.

STEP 4 - Tighten

Sealing Nut

STEP 1

Drill Hole

O 22mm

401345-5_RB_LevelSwitch_I&OI.indd   2

23/11/2016   3:34 PM