Step 4 - Installing the Manifolds and Balance Pipe
The balance pipe (not included in kit) should PN12 PVC-U pressure pipe that can be sourced through most plumbing
supply outlets. The balance pipe ensures equal pressure and flow rates throughout the collector system, and is
required to ensure the correct operation and performance of the system.
• Slide the pre-glued
RETURN
(front) Manifold assembly into the T-slot of the fixed Roof Mounts
• Clip the pre-glued
SUPPLY
(middle) Manifold assembly into the centre clip of the Roof Mount
• Clip the Balance pipe into the rear clip of the Roof Mount