4
Location
The pump should be located as close to the water as practicable and mounted on a firm
base in a well-drained position, high enough to prevent any flooding. It is the installer’s
responsibility to locate the pump such that the nameplate can be easily read and it can
be readily accessed for service. The four holes in the base shall be fixed on the ground
(alternatively, this can be with a rubber pad and/or mounting frame) after installing the pump.
Weather Protection
It is recommended that the pump is protected from the weather.
Power Connection
IMPORTANT INFORMATION:
If equipotential bonding structure is required, then a
Equipotential Bonding Point is provided. (Please refer to your local wiring standard
and regulations).
Davey StarFlo DSF150CE, DSF200CE, DSF250CE, DSF300CE and DSF420CE pool pumps
are suitable for connection to a nominal 220-240 volt 50Hz power supply and are equipped
with a flex lead. If a power outlet is not available within 3 metres of the pump, a power point in
a safe, dry place may need to be provided by an electrician/electrical contractor.
Davey StarFlo DSF3003FCE and DSF4203FCE pool pumps are suitable for connection
to a nominal 380-415 volt 50Hz power supply and are equipped with a flex lead. Power
connection needs to be provided by an electrician/electrical contractor.
Davey StarFlo DSF150, DSF200, DSF250, DSF300 and DSF420 pool pumps are suitable for
connection to a nominal 220-240 volt 50Hz power supply and are equipped with a flex lead
and 3 pin plug. If a power outlet is not available within 3 metres of the pump, a 3 pin power
point in a safe, dry place may need to be provided by an electrician/electrical contractor.
Extension cords are unsafe around pools – and should be avoided. If the supply cord
of this product is damaged it must be replaced by the Dealer or distributor, with genuine
Davey spares.
ATTENTION: Davey Water Products recommends that all installations are
fitted with earth leakage or residual current protection devices. Power supply
to this pump needs to be through an isolating transformer or RCD, having
a rated operating current not exceeding 30mA. In the interests of safety, we
advise that the installation must be in accordance with AS3000 wiring rules,
or local equivalent. Ensure that an electrical isolation switch be located
within easy access so that the pump can be turned off in an emergency.
ATTENTION: In accordance with AS/NZS 60335.2.41 we are obliged to inform
you that this pump is not to be used by children or infirm persons and must not
be used as a toy by children. If the pump and filter are located below pool water
level, it is necessary to fit isolating valves in the pipe between the pump and the
skimmer box and in the return pipe between the pump and the filter.
IMPORTANT: The fittings on this product are constructed of ABS. Some PVC jointing
compounds are incompatible with ABS. Check compound suitability before use.