Evaporative coolers, RO filters and extra draw-off capacity

Where a Torrium2 equipped pump is required to supply water to an evaporative cooler, 

reverse osmosis (R.O.) filter or similar low flow device, the Torrium2 will detect the 

limited demand. This will result in the Torrium2 adapting to the slow demand. The pump 

start pressure will be allowed to drop to a lower cut in pressure each time low flows are 

detected. To provide the maximum draw-off from the additional pressure tank, the tank’s 

pre-charge should be set at 45% of the pump shut-off pressure.
If normal flow is required from your system, Torrium2 will initiate instant start.
Fit the Supercell pressure tank downstream of the controller.

DO NOT USE THREAD SEALING COMPOUNDS, HEMP OR PIPE DOPE!

Suction Lines / Lift

The Torrium2 controller has an in-built non-return (check) valve fitted. In flooded suction 

installations there is no need to have a suction non-return valve.
Installations with flooded suction require a gate or isolating valve so water supply can be 

turned off for pump removal and servicing.
In suction lift installations a footvalve will normally be required for the pump to retain prime.
In some suction lift installations there may be good reason to remove the o-ring from the 

inbuilt check valve to ensure that the discharge pressure is also applied to the suction 

line and footvalve. (NOTE: The check valve, minus the o-ring, needs to be replaced in the 

Torrium2 controller to properly direct water flow over the flow sensor.) Removing the o-ring 

from the inbuilt check valve could be where the suction line was very long or where there 

was concern regarding a leaking footvalve. This may not always be applicable and it is 

acceptable to retain the inbuilt check valve in the Torrium2 on suction lifts with good suction 

plumbing.
Should the o-ring of the inbuilt check valve be removed though, an additional accumulator 

should be fitted to the discharge pipework as applicable, to ensure the pump is not cycled 

on shut down. The size of this accumulator will depend on the size, length and type of 

pipe used on the suction.

Abrasive Materials - The pumping of abrasive materials will cause damage to the 

pressure system which will then not be covered by the guarantee.

Discharge Connections

The Torrrium2 offers the option of using one or both outlet options.

Use of the horizontal outlet only allows for either:

1. Easy access to prime the pump and / or the removal of the inbuilt Torrium check valve

2. Fitment of a pressure tank (up to 20 litre capacity) onto the priming port / vertical 

discharge port.

  For optimal draw off, see section on “Extra Draw-off Capacity.”
If you use the vertical outlet instead or as well, you need to consider access to the inbuilt 

check valve in the Torrium.  Davey suggest you use a flexible connection and / or union 

connection to allow for ease of access to the check valve.

Summary of Contents for Torrium 2 TT45

Page 1: ...lieved Failure to observe this warning will expose persons to the possibility of personal injury and may also result in damage to the pump pipework or other property WARNING Failure to follow these in...

Page 2: ...pump run out of water or overheat should the pump fail to start due to low voltage or a blockage in the pump 3 Provides an easy to understand visual representation of the system status 4 Has adaptive...

Page 3: ...s commonly used worldwide special models with power leads to suit particular regions or countries are made For example for North America 110 120V 60Hz models use suffix Y USA and 220 240V 60Hz models...

Page 4: ...s thread sealing tape may be needed Fitting the P No 32574 adaptor flange for adapting to earlier Hydrascan and Torrium flanges First fit the Torrium2 controller with the adaptor flange using a thread...

Page 5: ...e suction line and footvalve NOTE The check valve minus the o ring needs to be replaced in the Torrium2 controller to properly direct water flow over the flow sensor Removing the o ring from the inbui...

Page 6: ...onnection must be incorporated in the fixed wiring in accordance with the wiring rules The electrical connections and checks must be made by a qualified electrician and comply with applicable local st...

Page 7: ...se consult your Davey Dealer for assistance Where the Davey pump involved has not had a controller fitted before use the wiring details below as a guide After half an hour of constant running Torrium2...

Page 8: ...t Should it be consumed due to power spikes it will almost always blacken the viewing port This will indicate a non warrantable failure WARNING Automatic reset thermal overloads may allow the pump to...

Page 9: ...disassembled Failure to observe this warning will expose persons to the possibility of personal injury and may also result in damage to other property Do not dismantle no user serviceable parts spring...

Page 10: ...s a problem e g low voltage at pump excessive ambient temperature above 50 C in pump enclosure b The Torrium2 control device may have to be reset after rectifying any of the above operating troubles T...

Page 11: ...ustomer from the service center at Davey s cost 3 This guarantee is subject to due compliance by the original purchaser with all directions and conditions set out in the In stallation and Operating In...

Page 12: ...g the product to the place of purchase is at your cost and is your responsibility The warranty claim will be assessed by Davey on the basis of their product knowledge and reasonable judgement and will...

Reviews: