Your Torrium2 controller is an electronic flow control device – a Davey 
designed product that enables the use of a highly efficient pump design and 
offers the following benefits:–

1.  Enables the pump to deliver a constant flow of water particularly at 

low flow rates – reducing the inconvenience of pressure variation in 
showers etc.

2.  Provides automatic “cut-out” protection should the pump run out of 

water or overheat*, should the pump fail to start due to low voltage or a 
blockage in the pump.

3.  Provides an easy to understand visual representation of the system status.
4.  Has adaptive pressure cut-in which allows the pump to start at 

approximately 80% of the maximum pressure at last shut-down.  This 
allows the controller to accommodate varying inlet pressures and pump 
performance.

5.  Automatic retry functions in the event of a critical system fault.
6.  Pressure indicator so you can easily tell what the pressure in your water 

supply system is doing.

7.  Easy visual guide to the status of the inbuilt surge arrestor.
8.  Choice of both vertical and horizontal outlets.

* Motor overload / overheat protection is also included. Motor must also 
have its own overload / overheat protection.

Before installing your Torrium2 controller, please read all instructions carefully as 
failures caused by incorrect installation or operation are not covered by the guarantee. 
Your Torrium2 controller is designed to handle clean water. The system should not be 
used for any other purpose without specific referral to Davey. The use of the system to 
pump flammable, corrosive and other materials of a hazardous nature is specifically 
excluded.

2

15

Congratulations on your purchase of a high quality, Australian built Davey 
Torrium2 controller. All components have been designed and manufactured 
to give trouble free, reliable operation.
Prior to using this controller you must ensure that:

•  The controller is installed in a safe and dry environment

•  The controller enclosure has adequate drainage in the event of leakage

•  Any transport plugs are removed

•  The pipe-work is correctly sealed and supported

•  The pump is primed correctly

•  The power supply is correctly connected

•  All steps have been taken for safe operation
Appropriate details for all of these items are contained in the following 

Installation and Operating Instructions. Read these in their entirety 

before switching on this controller. If you are uncertain as to any of these 

Installation and Operating Instructions please contact your Davey dealer or 

the appropriate Davey office as listed on the back of this document.

Summary of Contents for Torrium2

Page 1: ...difficulties or if the product is faulty or defective advise you on how to have your Davey product repaired obtain a replacement or a refund Your Davey Two Year Guarantee naturally does not cover nor...

Page 2: ...Before installing your Torrium2 controller please read all instructions carefully as failures caused by incorrect installation or operation are not covered by the guarantee Your Torrium2 controller is...

Page 3: ...60Hz models use suffix Y USA and 220 240V 60Hz models use suffix P USA Fitment of the Torrium2 controller The Torrium2 controller fits onto the outlet of the pump The Torrium2 controller is designed t...

Page 4: ...able to be used as a discharge port During servicing use only approved non petrochemical based oring and gasket lubrication If unsure consult your Davey Dealer for advice WARNING Do not use hydrocarbo...

Page 5: ...socket since both Torrium2 prime port and tank are 1 male threads DO NOT USE THREAD SEALING COMPOUNDS HEMP OR PIPE DOPE Trouble Shooting Check List a PUMP HAS STOPPED OR MOTOR RUNS FOR SHORT PERIOD ON...

Page 6: ...er access to the inbuilt check valve in the Torrium Davey suggest you use a flexible connection and or union connection to allow for ease of access to the check valve Pipe Connections For best perform...

Page 7: ...we are obliged to inform you that this appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they ca...

Page 8: ...Water return mode will restart the pump automatically if the Torrium2 detects water flow through it Electrical Power Surge Protection An electrical power surge or spike can travel on the supply lines...

Reviews: