Fitting the Torrium2 directly to the Pump

The Torrium2 is fitted with a rotary coupling. This coupling allows the pump 
controller to be fitted simply and easily to the pump discharge on models 
with 1” female outlets.

For Davey models the coupling has an oring 
seal. If used on other brands, thread tape 
may be required. The controller adaptor nut 
is able to rotate independent of the Torrium2 
and the complete pump, this allows it to be 
tightened onto the pump easily. For ease 
of installation a tightening tool is included 
with Torrium2 to tighten the controller nut to 
ensure a firm connection to your controller.

The ability to rotate the adaptor nut also means that the complete controller, 
once fitted to the pump, can be rotated a full 360

o

 in the horizontal plane, 

without causing the coupling to unscrew from the pump outlet.

For pumps with a 1” male outlet (e.g. XP350, XP450, XJ50, XJ70 and 
XJ90) a adaptor socket (P/No. 44992) is required. Thread sealing tape will 
be needed when using this adaptor socket to ensure a watertight seal.

Fitting the P/No. 32574 adaptor flange for adapting 
to earlier Hydrascan and Torrium flanges.

First, fit the Torrium2 controller with the adaptor flange using a thread tape 
to seal, then fit the Torrium2 to the existing union nut on the pump. 

DO NOT 

OVERTIGHTEN!

The control unit is capable of 360° rotation without loosening the nut, to 
enable the most convenient positioning of the discharge piping. 

4

13

With Torrium2 you can connect the discharge pipework to the 
discharge port and/or the vertical priming port. The priming port is 
able to be used as a discharge port.

During servicing, use only approved, non-petrochemical based 

oring and gasket lubrication. If unsure, consult your Davey Dealer 

for advice.

 

WARNING: Do not use hydrocarbon based or hydrocarbon

 

propelled sprays around the electrical components of this

 controller.

NOTE:
a)  For protection, Davey pump motors are fitted with an automatic “over 

temperature” cut-out. Constant tripping of this overload device indicates a 
problem e.g. low voltage at pump, excessive ambient temperature (above 50°C) 
in pump enclosure.

b)  The Torrium2 control device may have to be reset after rectifying any of the 

above operating troubles. This is done by pushing in the “prime” button and 
releasing it after 2 seconds, or switching the power supply off then on.

 

Care should also be taken when servicing or disassembling pump

 

to avoid possible injury from pressurised water. Unplug pump,

 

relieve pressure by opening a tap on the discharge side of the

 

pump and allow any hot water in the pump to cool before

 

attempting to dismantle.

WARNING: When servicing or attending pump, always ensure power 
is switched off and lead unplugged. Electrical connections should be 
serviced only by qualified persons. If the electrical supply lead of this 
controller is damaged, the unit must be replaced.

NOTE:  The Torrium2 controller is adaptive.  If your pump draws air or is subject to 
blockage, the Torrium2 adapts to its new maximum pressure.  This may result in 
your system pressure not dropping below the new cut-in pressure and your pump 
not starting.  This is more likely to occur when boosting mains pressure. Should this 
occur, re-prime your pump unit.  Should this not prove successful, it is likely you have 
a blockage in the pump.  You should contact your Davey dealer for assistance.

Summary of Contents for Torrium2

Page 1: ...difficulties or if the product is faulty or defective advise you on how to have your Davey product repaired obtain a replacement or a refund Your Davey Two Year Guarantee naturally does not cover nor...

Page 2: ...Before installing your Torrium2 controller please read all instructions carefully as failures caused by incorrect installation or operation are not covered by the guarantee Your Torrium2 controller is...

Page 3: ...60Hz models use suffix Y USA and 220 240V 60Hz models use suffix P USA Fitment of the Torrium2 controller The Torrium2 controller fits onto the outlet of the pump The Torrium2 controller is designed t...

Page 4: ...able to be used as a discharge port During servicing use only approved non petrochemical based oring and gasket lubrication If unsure consult your Davey Dealer for advice WARNING Do not use hydrocarbo...

Page 5: ...socket since both Torrium2 prime port and tank are 1 male threads DO NOT USE THREAD SEALING COMPOUNDS HEMP OR PIPE DOPE Trouble Shooting Check List a PUMP HAS STOPPED OR MOTOR RUNS FOR SHORT PERIOD ON...

Page 6: ...er access to the inbuilt check valve in the Torrium Davey suggest you use a flexible connection and or union connection to allow for ease of access to the check valve Pipe Connections For best perform...

Page 7: ...we are obliged to inform you that this appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they ca...

Page 8: ...Water return mode will restart the pump automatically if the Torrium2 detects water flow through it Electrical Power Surge Protection An electrical power surge or spike can travel on the supply lines...

Reviews: