Where the Davey pump involved has not had a controller fitted before, use 
the wiring details below as a guide.

Status Indicator

The Torrium2 has a status indicator lights on the front panel. These lights 

will enable you to understand what your pump is doing.

  Condition

 Indicator readout

  Pump operation

  Restart / Reset Method

  Standby mode

  Red light

  Standby

  Pressure drop

  Running

  Green light

  Running

  N/A

  Fault

  Yellow light

  Stops, auto-retry &
  ‘water return’ activated

  Push ‘Prime’ button or
  cycle power off / on

Only one fault condition will be indicated at once.

Pressure Indicator Window

Torrium has an easy to read pressure indicator window on the side of the 
inbuilt pressure vessel – see Figure 1 on page 3.  
If the pressure is low the window will show mainly red.  If the pressure is at 
maximum (i.e. 450kPa for T45 and 700kPa for T70 models) the window will 
show mainly green.
The window can also help analyse the occurrence of unwanted leaks. If the 
colour band in the window is moving towards red, this shows that pressure 
is decreasing.  If the colour band in the window is moving towards green, 
this shows that pressure is increasing.

Auto-retry and Water Return Modes

Should your Torrium2 detect a loss of prime, after stopping the pump, it 
will wait five minutes before activating Auto-retry and Water Return modes.  
Auto-retry automatically starts the pump to see if the pump is now primed.  
It does this after 5 mins, 30 mins, 1 hr, 2 hrs, 8 hrs, 16 hrs and 32 hrs.  
Water return mode will restart the pump automatically if the Torrium2 
detects water flow through it.

Electrical Power Surge Protection

An electrical power surge or spike can travel on the supply lines and cause 
serious damage to your electrical equipment. The Torrium2 controller  has a 
metal oxide varistor (MOV) fitted to help protect it’s circuit. The MOV is not 
a lightning arrestor and may not protect the Torrium2 controller if lightning or 
a very powerful surge hits the pump unit.
If the installation is subject to electrical power surges or lightning we 
strongly recommend the use of a suitable surge protection device on ALL 
electrical equipment.

Surge Protector Status Window

To allow you to check the status of the inbuilt MOV in the Torrium2 there is 
a viewing window at the back of the Torrium2 above the power lead entry 
/ exit grommet. The MOV is the blue disc shaped component. Should it be 
consumed due to power spikes it will almost always blacken the viewing 
port. This will indicate a non-warrantable failure.

The colour codes for the terminations are as below:

Voltage 

Active 

Neutral 

Earth

110-240V 50/60Hz
& 220-240V 60Hz 

Brown 

Blue 

Green / Yellow 

for Nth America
110-115V 60Hz

 

Black 

White 

Green

for Nth America

Where you are replacing an existing Davey Torrium, Davey Hydrascan, 

Davey Presscontrol or Davey pressure switch, the connections should be 

identical for the Torrium2 controller. See the underside of the capacitor 

cover for a wiring diagram.
The exception to this rule is where the special four wire Hydrascan fitted 

to the M series models or USA models is to be replaced. In such a case 

consult your Davey Dealer for assistance.

Summary of Contents for Torrium2

Page 1: ...difficulties or if the product is faulty or defective advise you on how to have your Davey product repaired obtain a replacement or a refund Your Davey Two Year Guarantee naturally does not cover nor...

Page 2: ...Before installing your Torrium2 controller please read all instructions carefully as failures caused by incorrect installation or operation are not covered by the guarantee Your Torrium2 controller is...

Page 3: ...60Hz models use suffix Y USA and 220 240V 60Hz models use suffix P USA Fitment of the Torrium2 controller The Torrium2 controller fits onto the outlet of the pump The Torrium2 controller is designed t...

Page 4: ...able to be used as a discharge port During servicing use only approved non petrochemical based oring and gasket lubrication If unsure consult your Davey Dealer for advice WARNING Do not use hydrocarbo...

Page 5: ...socket since both Torrium2 prime port and tank are 1 male threads DO NOT USE THREAD SEALING COMPOUNDS HEMP OR PIPE DOPE Trouble Shooting Check List a PUMP HAS STOPPED OR MOTOR RUNS FOR SHORT PERIOD ON...

Page 6: ...er access to the inbuilt check valve in the Torrium Davey suggest you use a flexible connection and or union connection to allow for ease of access to the check valve Pipe Connections For best perform...

Page 7: ...we are obliged to inform you that this appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they ca...

Page 8: ...Water return mode will restart the pump automatically if the Torrium2 detects water flow through it Electrical Power Surge Protection An electrical power surge or spike can travel on the supply lines...

Reviews: