background image

USER’S MANUAL 

MA24-02/B 

 

10 

4. SETUP 

 
Switch ON the scale and long press [ZERO]

[ZERO]

[ZERO]

[ZERO] key for 3 seconds. First “SETUP” and then “A.OFF” will display 

successively.  
 
Auto-off time setup 
This enables operator to select the auto turn OFF time of the device. 
Auto off time:

Auto off time:

Auto off time:

Auto off time: 120 sec/180 sec/240 sec/300 sec/Off 
 
Buzzer on/off setup 
This enables operator to select beep sound ON/OFF. 
Buzzer:

Buzzer:

Buzzer:

Buzzer: On/Off 
 

    

NOTE: To confirm the settings, please press HOLD when “END” displays on the display. 

 
 

4.1

4.1

4.1

4.1. . . . CONNECTING W

CONNECTING W

CONNECTING W

CONNECTING WITH PC

ITH PC

ITH PC

ITH PC    

The equipment can be connected to PC to transfer the weighing results. 
    
1.

 

Start Hyper Terminal 
Start Hyper Terminal program from clicking: Start Menu 

 Programs 

 Accessories 

 Communication 

 

Hyper Terminal. 

 
2.

 

New Connection Description 
Give new connection a name then click OK.  

 
3.

 

Select Your COM Port 
Click Connect to select your COM port. Usually there’s only one option for select. Then click OK. 

 
4.

 

Port Settings 
Click Bits per second to set up rate at 9600, Data bits at 8, Parity at None, Stop bits at 1 and Flow control at 
Hardware. Then click OK to complete your setting. 

 
5.

 

Output Data 
When the patient has been weighed and BMI calculated, simply press the PRINT key to output data from scale 
to PC or an Optional Printer. 

    
Parameters of RS232 interface 
 
Set parameters of the scale interface on the connected device. It is not possible to change the scale parameters. 
 

o

 

Baud rate: 9600 bps  

Summary of Contents for CS2300S

Page 1: ...CS2300S USER S MANUAL MA24 02 B 12 09 2011 www davicia com...

Page 2: ...1 5 5 5 5 MAINTENANCE MAINTENANCE MAINTENANCE MAINTENANCE AND CLEANING AND CLEANING AND CLEANING AND CLEANING 5 1 Instructions for charge and connect 5 2 Instructions for replacing batteries 5 3 Envir...

Page 3: ...USER S MANUAL MA24 02 B 3 1 DESCRIPTION 1 Display unit 2 Access ramps 3 Scale platform 4 Carry handle 5 Level 2 4 3 1 5...

Page 4: ...o Ensure the voltage marked on the power supply unit matches your main power supply o This device is designed for use indoors o Observe the permissible ambient temperatures for use o The device meets...

Page 5: ...cription 0 Zero symbol If the scale does not show exactly zero value although the scale pan is unloaded press the 0 0 0 0 key After a short waiting time the scale will be zeroed again Stable symbol If...

Page 6: ...merical value Entering digits 3 3 3 3 3 3 3 3 WEIGHING WEIGHING WEIGHING WEIGHING Switch on the scale with the ON OFF ON OFF ON OFF ON OFF key The diagnostic scale self check is performed and then the...

Page 7: ...ale takes some measuring values and then the calculated average value is displayed o Remove the object baby from the scale platform The object baby s weight reading will remain on the display o Press...

Page 8: ...tare weight For example Press 1 to assign position 1 to preset tare weight The display will blink and makea beep sound NOTE You can assign any other position from 1 5 to pre tare weight Enter Weight U...

Page 9: ...e Long press PRE TARE key for 3 seconds the display will show the blinking m sign Press numeral key 1 5 to choose pre Press numeral key 1 5 to choose pre Press numeral key 1 5 to choose pre Press num...

Page 10: ...nected to PC to transfer the weighing results 1 Start Hyper Terminal Start Hyper Terminal program from clicking Start Menu Programs Accessories Communication Hyper Terminal 2 New Connection Descriptio...

Page 11: ...NT FUNCTION The Weighing BMI and Height results can be printed out for records using RS232 interface cable included in accessory kit which is connected with the round plug at the back terminal After w...

Page 12: ...RUCTIONS FOR REPLACING BATTERIES INSTRUCTIONS FOR REPLACING BATTERIES INSTRUCTIONS FOR REPLACING BATTERIES INSTRUCTIONS FOR REPLACING BATTERIES o Remove the battery cover o Take the battery housing ou...

Page 13: ...fault on the scales such as faulty load cell or wiring Please contact the local service representative Counting error too low Indicates that the signal from the load cell is too low This error is nor...

Page 14: ...300 kg x 100 g LCD Display 1 0 inch LCD display with 5 and 1 2 digits Max external dimensions 1150 x 800 x 66 mm Power supply AC adapter 15V 300mA Rechargeable Battery Key Functions ON OFF ZERO PRINT...

Page 15: ...ied free of charge upon presentation of the purchase receipt for the appliance No other rights can be taken into consideration Return shipment is at the customer s expense if the appliance is anywhere...

Page 16: ...NICO Type Electronic equipment Finalidad Prevista Equipo pesapersonas Intended Use Weighing equipment CUMPLE LOS REQUISITOS DE LAS DIRECTIVAS CONFORMS WITH THE REQUISITES OF THE DIRECTIVES EC Directiv...

Page 17: ...ments are available on the web www davicia com www davicia com www davicia com www davicia com C Murcia 35 Nave G Pol industrial Can Calder n E 08830 Sant Boi de Llobregat Barcelona Spain Tel 34 93 65...

Reviews: