U3800 MASTER STATION 

 

DESCRIPTION 

 
The  U3800  Master  Station  is  the  heart  of  the  David  Clark  Company  Series  3800  Intercom 
System.    The  3800  adjusts  automatically  for  12  or  24  VDC  power  source.    It  contains  system 
on/off and volume controls, power input and a remote output, system fuse, plus 2 headset jacks. 
 

INSTALLATION 

 
1.  Select a mounting location where the headset cord will not interfere with the operator's job 

function or otherwise force actions that may jeopardize safe operation. 

 

WARNING 

 

Caution should be taken with the U3800 when selecting a mounting 
position so that it's at least 2 feet away from the transmitter antenna. 

 

2.  Mount the U3800 by placing one grommet between each of the four mounting brackets and 

the  mounting  surface.    Grommets  are  provided  with  the  module  but  fasteners  are  not.    The 
type of fastener selected should be based on mounting location. 

 
3.  A C3820 Power Cord, twenty feet in length, is required to connect a U3800 Master Station 

to  it's  power  source.    The  stripped  and tinned end  of the  C3820 incorporates  a fuse holder 
with a 2 amp slo-blow fuse.  If connecting to a vehicle's power source, consideration should 
be given to whether you connect before or after the ignition switch.  The red wire should be 
connected  to  DC  positive (power) and  the  black  wire  should  be connected  to  DC  negative 
(ground).  Connect the two pin (male) connector of the negative (ground).  Connect the two 
pin (male) connector of the power cord to the power input connector located on the Master 
Station. 

 

NOTE:

  It is recommended that a Noise Suppression Kit, such as 

Radio Shack P/N 270-030 or equivalent, be installed on the 
power line to the U3800 Master Station to help prevent 
electrical noise from entering the intercom system.  Install 
the filter at the point where power is derived. 

 
4.  All cords have military type screw-on connectors.  Install cords as follows: 
 
 

a.  Align key-way slot on cord connector with key in threaded connector on module. 

 

b.  Insert pins into socket until firmly seated. 

 

c.  Hand tighten swivel nut on cord connector. 

 
5.  Connect Master Station to Remote Modules using (C38-XX) Jumper Cords of desired 

length. 

 

 