background image

-9-

OPERATION

!

WARNING

  Do not subject the 

instrument to 

extreme temperatures or variations in 

temperature.

 As an example, do not 

leave it in vehicles for long time. In 

case of large variations in 

temperature, allow the instrument to 

adjust to the ambient temperature 

before putting it into operation. In 

case of extreme temperatures or 

variations in temperature, the 

accuracy of the instrument can be 

impaired.

Avoid heavy impact to or falling 

down of the instrument.

 After severe 

exterior effects to the instrument, 

it is recommended to carry out an 

accuracy check  each time before 

continuing to work.
This laser tool is a precision 

instrument and should be treated 

with care. 

When not in use, the pendulum 6 

should always be in the OFF position. 

Locking the pendulum 

6

 allows the 

laser to better withstand vibration and 

trauma incurred during transportation 

or if the unit is dropped.

Switching On and Off

To switch on the tool, slide the On/

Off switch 

to the   position (when 

working without automatic leveling) 

or to the 

ON

 position (when working 

with automatic leveling). 
Immediately after switching on, the 

tool sends laser beams out of the exit 

openings.

Operating Modes

The tool has total of three operation 

modes that can be switched through 

in sequence:
–  Horizontal Layout Operation: 

Produces a 360-degree horizontal 

laser plane

–  Vertical Layout Operation: 

Produces a two vertical laser 

planes at a 90° angle 

–  3-Plane Layout Operation: 

Produces a horizontal laser line in 

the front.

After switching on, the tool is in 

horizontal layout operating mode with 

self-leveling. To change the operating 

mode, press the operating mode 

button 

1a

 as often as required until 

the requested operating mode is set.
All operating modes can be selected 

both with and without automatic 

leveling.

Summary of Contents for LL360P

Page 1: ...www davidwhite us com LL360P LL360P Laser Owner s Guide FOR CUSTOMER SERVICE PARTS AND REPAIR CALL 765 581 4097 IMPORTANT IMPORTANT IMPORTANTE Read Before Using Lire avant usage Leer antes de usar ...

Page 2: ...xtremely rugged field use Like all precision instruments however they should be treated with reasonable care to prolong life and accuracy All instruments are adjusted when they are shipped from the factory It is the customer s responsibility to check and to ensure instruments are adjusted prior to using David White is not responsible for errors caused by instruments that are out of adjustment Cont...

Page 3: ... 3 1 2 4 3 5 6 LL360P b c d e a ...

Page 4: ...may result in hazardous radiation exposure ALWAYS make sure that any bystanders in the vicinity of use are made aware of the dangers of looking directly into the laser tool DO NOT place the laser tool in a position that may cause anyone to stare into the laser beam intentionally or unintentionally Serious eye injury could result ALWAYS position the laser tool securely Damage to the laser tool and ...

Page 5: ...ery chemistries Dispose of or recycle batteries per local code DO NOT dispose of batteries in fire Keep batteries out of reach of children Personal safety Stay alert watch what you are doing and use common sense when operating a tool Do not use a tool while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating a tool may result in serious perso...

Page 6: ...f Any tool that cannot be controlled with the switch is dangerous and must be repaired Store idle tool out of the reach of children and do not allow persons unfamiliar with the tool or these instructions to operate the tool Tools are dangerous in the hands of untrained users Maintain tools Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect t...

Page 7: ... for laser beam produces 360 degree horizontal laser line 3 Exit opening for laser beam produces 360 degree vertical laser line from the side 4 Exit opening for laser beam produces 360 degree vertical laser line from the front 5 Battery compartment lid 6 Switch for automatic leveling locking the unit Technical Data Description LL360P Accuracy 1 4 in at 100 ft 3mm at 15m Range 65 ft 20m Range with ...

Page 8: ...xtended periods the batteries can corrode and discharge themselves To open the battery compartment 5 press on the latch and fold the battery lid upward Insert the batteries When inserting pay attention to the correct polarity according to the and icons inside of the battery compartment Use either alkaline batteries or Ni Mh batteries When inserting alkaline batteries pay attention to the correct p...

Page 9: ...o better withstand vibration and trauma incurred during transportation or if the unit is dropped Switching On and Off To switch on the tool slide the On Off switch 6 to the position when working without automatic leveling or to the ON position when working with automatic leveling Immediately after switching on the tool sends laser beams out of the exit openings Operating Modes The tool has total o...

Page 10: ...e the model number and serial number of the instruments All precision instruments should be cleaned lubricated checked and adjusted ONLY at a qualified instrument repair station or by the manufacturer at least once a year In case of repairs send in the instrument packed in its protective case ENVIRONMENT PROTECTION Recycle raw materials batteries instead of disposing of waste The unit accessories ...

Page 11: ...A 90 DAY LIMITED WARRANTY To make a claim under this Limited Warranty you must return the complete product transportation prepaid For details to make a claim under this Limited Warranty please visit www davidwhite com or call 1 855 354 9881 ANY IMPLIED WARRANTIES SHALL BE LIMITED IN DURATION TO ONE YEAR FROM DATE OF PURCHASE SOME STATES IN THE U S AND SOME CANADIAN PROVINCES DO NOT ALLOW LIMITATIO...

Page 12: ...42347DLL360 10 15 Printed in China Dave White s SitePro 7619 S 1150 E Otterbein IN 47970 Tel 1 765 581 4097 ...

Reviews: