2. Place a flat washer, a lock washer and a hex nut on each of the bolt ends. 

3. Using an adjustable wrench or 7/16" wrench, tighten the nuts.

4. Place the second U-bolt around the pole and through the two holes at the bottom 

of the shelter. 

5. Put a flat washer, a lock washer, and a hex nut on each bolt end, and tighten the 

hex nuts. 

Note: 

If no soil temperature probe is used, the console will use a default temperature of 75ºF (24ºC) to 
compensate the soil moisture sensor readings. 

6. To prevent fraying or cutting of cables, secure 

them so they will not whip about in the wind. 
Secure a cable to a metal pole by wrapping elec-
trical tape around them both. Make sure cables 
are secure by placing clips or ties approximately 
every 3 – 5' (1 – 1.6 m).

Note: 

Do not use metal staples or a staple gun to secure cables. Metal staples — especially when 
installed with a staple gun — have a tendency to cut the cables.

Rules for Using Leaf, Soil and Temperature Sensors

The following station and sensor configurations are supported by the Leaf/Soil Sta-
tion:

• A station configured as a LEAF station in the console will support two leaf wet-

ness sensors and two leaf temperature probes.

• Leaf temperature probes can be used as you wish to measure air, water, or soil 

temperature. Leaf temperature does not affect leaf wetness readings.

• A station configured as a SOIL station in the console will support four soil mois-

ture sensors and four soil temperature probes.

• If you have installed any soil moisture sensors (SOIL 1, SOIL 2, SOIL 3, SOIL 

4), the corresponding temperature probes (TEMP 1 for SOIL 1, etc.) will be used 
to provide temperature compensation for the soil moisture sensor readings. 

• If you want to use a temperature sensor for something besides compensation for a 

soil moisture sensor, then you cannot use the corresponding soil moisture sensor.

Station Type in 

Console 

Configuration

Number of Leaf 

Wetness 

Sensors

Number of Soil 

Moisture 

Sensors

Number of

Temperature 

Probes

LEAF/SOIL Station

2

4

4

LEAF Station

2

-

2

SOIL Station

-

4

4

Cable Clip

Cable Tie

Securing Cables with Clips and Ties

Summary of Contents for 6345

Page 1: ...the Station supports two leaf wetness sensors and two temperature probes Configured as a Soil Station it supports up to four soil moisture sensors and tem perature probes Note In any station using so...

Page 2: ...U Bolts 1 4 Flat Washers 1 4 Lock Washers 1 4 Hex Nuts Leaf Soil Station Components 8 Wood Screws U Bolts 1 4 Flat Washers 1 4 Hex Nuts Leaf Wetness Sensor with 40 12 2 m of cable 8 x 3 4 Machine Scr...

Page 3: ...sing soil moisture readings page 17 If you encounter difficulties or have questions about your station the following additional information may be helpful Troubleshooting the sensors page 18 Extending...

Page 4: ...sture Sensor Connection Temporarily connect a soil moisture probe to the SOIL 1 terminal block connector using the following instruc tions 1 Use a pen or small screwdriver to open the connector jaws a...

Page 5: ...tter ID Note A transmitter and receiver communicate with each other only when both are set to the same ID The factory default transmitter ID is 1 Looking at the table below you can see that means the...

Page 6: ...ill set the console to recognize signals on that ID as coming from a Leaf Soil Station 3 Press the left or right arrows to scroll through transmitter IDs When you see the ID you chose for the Leaf Soi...

Page 7: ...nfirms communication between your Leaf Soil Station and the console Disconnect the sensor s that were temporarily installed to test communica tions Go on to Choosing a Location to Mount the Station on...

Page 8: ...ith 15 4 6 m of cable standard and can be extended up to 1000 300m using 18 gauge UF cable Temperature Sensors come with 15 4 6 m of cable standard and can be extended up to 800 242m using 24 AWG shie...

Page 9: ...in the area it may interfere with the signal For example if the transmitter is mounted downhill from the console receiver the ground may block a wide angle of the transmitted signal Mounting the Leaf...

Page 10: ...e Sensors The following station and sensor configurations are supported by the Leaf Soil Sta tion A station configured as a LEAF station in the console will support two leaf wet ness sensors and two l...

Page 11: ...station to detect the presence of surface mois ture on foliage and calculate the duration of wetness When moisture is present the sensor detects an electrical resistance change between the gold plate...

Page 12: ...ately every 3 5 1 1 6 m Note Do not use metal staples or a staple gun to secure cables Metal staples especially when installed with a staple gun have a tendency to cut the cables Mounting the Sensor A...

Page 13: ...need for water This minimizes the guesswork resulting in water savings lower pumping costs and the elimination of excess leaching of nitrogen due to over irrigation While not absolutely necessary for...

Page 14: ...e cables Locating Sensors Be aware of the soil variations in your field or lawn The lighter soils dry very quickly heavier soils more slowly Both conditions must be considered Furrow or Flood Irrigati...

Page 15: ...ing sure to stay in active root zones Drip or Micro Irrigation Place sensors in the wetted area With drip emitters this is usually 12 to 18 from the emitter With micro sprinklers or sprays usually 24...

Page 16: ...he sensor with a slurry made from the sample soil to get a snug fit in the soil 3 Always install sensors in the active root system of the crop with a snug fit in the soil Note In gravelly soils and wi...

Page 17: ...rature Sensors on page 13 6 If you withhold irrigation for several days and allow the soil to dry down a bit you should see the soil moisture readings start to creep upward 7 Usually you will not need...

Page 18: ...Wetness Sensor cables can be extended up to 200 61m using 6 conductor 26 AWG cable Soil Moisture Sensor cables can be extended up to 1000 300m using 18 gauge waterproof cable UF insulation is recomme...

Page 19: ...n operating Temperature 50 to 158 F 45 to 70 C Current Draw 0 14 mA average 30 mA peak at 4 to 6 VDC power Battery CR123A 3 Volt Lithium cell Battery Life 8 months without sunlight greater than 2 year...

Page 20: ...limits for a class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equ...

Reviews: