Installing Your Station
Page 11
Securing and Grounding the Sensor Array
After mounting the sensor array, secure the sensor array to the extension tube
as shown below.
Run the green grounding wire(s) to a proper ground such as a metal under-
ground water main or grounding rod (as in Davis’ optional Grounding Kit).
Running the Cable from the Sensor Array to the Console (or ICAM)
To prevent fraying or cutting of the 8-conductor cable, secure the cable so it
does not whip about in the wind. Secure it to the extension tube by wrapping
electrical tape around them both. To prevent rain from running along the cable
to your console, secure the cable underneath the eaves of your house or in
another location similarly shielded from rain; place cable clips or weather-
resistant cable ties approximately every 3-5 feet (1-1.6 m).
Note:
Do not use metal staples or a staple gun to secure the cable. Metal staples—especially when
installed with a staple gun—have a tendency to cut the cables.
Mounting the ICAM, Industrial Stations Only
Use the hardware provided to install the ICAM in a sheltered, weather-
protected area (or a Davis weatherproof shelter). Refer to the ICAM manual for
instructions, if necessary. Remember to ground the ICAM to a proper ground
such as a metal underground water main or grounding rod (as in Davis’
optional Grounding Kit).
Sensor Array
Extension
Tube
Hex
Nuts
Lock
Washers
Flat
Washers
1-1/8"
Saddles
1-1/2" x 5/16" U-Bolts;
torque until bolts dent
tubing slightly
2-1/2"