background image

Page 14

EZ-Mount Advanced Station

T

ROUBLESHOOTING

While the EZ-Mount Advanced Station is designed to provide years of trouble-
free operation, occasional problems may arise. If you experience a problem, 
please check the troubleshooting tips below before calling tech support.

Console does not register any rainfall

Double check that you have cut the cable tie that secures the rain bucket 

during shipping. See step 4 on page 5 for instructions. Also, make sure the 
anemometer is not positioned above the rain collector cone.

Console does not register wind direction correctly

Check that you have either pointed the anemometer arm westward when 
mounting (page 10), or that you have recalibrated the wind vane to the 
anemometer arm’s current direction. 

Console locks up

Insufficient power during power up or a power surge may cause the con-
sole to lock up. If this occurs, remove all power by disconnecting any bat-
tery backup and the 

AC/DC

 power cord. Wait for 1 minute with all of the 

power removed. Then re-connect the 

AC/DC

 power cord and listen for 2 

beeps within 10 seconds. 

Note:

If you have the WeatherLink installed, listen for 3 beeps within 20 seconds and then, if all 

is well, try communicating with the WeatherLink using the software. 

Once you receive the final beep, install a fresh backup battery, if desired, 
and put the console back into service.

Display is flashing 

Unit is operating under battery power. Check to be sure the power adapter 
has not come unplugged from the console or outlet. 

Display is blank 

Unit is not receiving power. Check to be sure the power adapter has not 
come unplugged from the console or outlet.
If power is interrupted, battery may be installed incorrectly. Check and re-
install. 
Battery may be run down or old. Replace.

Display shows a series of dashes in place of function reading 

Sensor for function which is "dashed out" is not plugged in.
Cable from sensor for function which is "dashed out" may have broken 
wire. Check the areas where cables have been secured carefully.
A reading has exceeded the limits indicated on the specifications table.
For temperature, wind speed, or rainfall: calibration numbers may be 
causing readings to exceed display limits. Check calibration number and 
adjust if necessary. 

Summary of Contents for Energy EnviroMonitor

Page 1: ...dard and industrial The industrial option offers greater protection from radio frequency interference electrostatic discharges and voltage surges by provid ing 100 feet of shielded cable an extra grou...

Page 2: ...ctor Cone EZ Sensor Arm Additional Components for INDUSTRIAL Installations Only ICAM Kit 8 Conductor Cable Standard for ICAM to Console 25 7 5m 16 5 5m Ground Wire 6x1 25mm Screws Cable Ties Adhesive...

Page 3: ...the extension tube page 4 Attach the anemometer page 4 Attach the wind cups page 4 Snip the cable tie in the rain collector page 5 Apply power to the console page 5 Attach the EZ Sensor Arm page 6 Con...

Page 4: ...s positioned over the white field case and NOT over the black rain collec tor cone 3 Attach the wind cups to the anemometer Push the wind cups onto the shaft as far as they will go then tighten the se...

Page 5: ...rge tab between the two oblong holes on the base s underside and pulling the base free Plug the power adapter into the center Power slot as shown below and then plug the other end into a 110 VAC outle...

Page 6: ...port tube insert the EZ Sensor Arm letting the wire drop through the bottom gap in the brace clamp and tighten Alternative EZ Sensor Arm Positioning You may face the sensors straight up as shown above...

Page 7: ...ere Note This alternative configuration is not standard for meteorological measurements Use the following rubric to determine the tilt angle for maximum readings Maximum Readings During Spring or Fall...

Page 8: ...d release the lever d Connect the bare drain wire to the SHIELD terminal JP2 and cut off any excess drain wire e Attach the ground wire to the SHIELD terminal JP2 as well Run the ground wire and the s...

Page 9: ...in the sensor array field case keeping in mind that you will need a power source you should locate the console indoors For more accurate readings follow these suggestions Avoid placing console in dir...

Page 10: ...the station facing a different direction see Recali brating the Wind Vane on page 12 for instructions on how to adjust the wind vane accord ingly Note For roof mounting we recommend the optional Mount...

Page 11: ...ble underneath the eaves of your house or in another location similarly shielded from rain place cable clips or weather resistant cable ties approximately every 3 5 feet 1 1 6 m Note Do not use metal...

Page 12: ...compass or local area map to determine which direction N S E W NE etc the anemometer arm is pointing 4 Use the wind direction chart to find the degree reading which corresponds to that direction 5 Sl...

Page 13: ...ON A SHELF Or to display the console on a wall follow these steps a Hold the mounting base flat against the wall and use a pencil to mark the location of the two keyholes b Use an electric drill with...

Page 14: ...AC DC power cord and listen for 2 beeps within 10 seconds Note If you have the WeatherLink installed listen for 3 beeps within 20 seconds and then if all is well try communicating with the WeatherLink...

Page 15: ...ly with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installati...

Page 16: ...iroMonitor and Health EnviroMonitor Systems Rev A Manual 7 8 99 Controlled online Weather Manuals Consoles EZ EZ Adv This product complies with the essential protection requirements of the EC EMC Dire...

Reviews: