4. Detach the rain collector cone and snip the cable tie. 

 

Detach the black rain collector cone from its base by rotating the cone 
counter-clockwise until its latches line up with the latch openings in the base 
and then raise the cone off. (The cone may be tightly attached to the base the 
first time.) C

 

arefully cut and remove the black cable tie which holds the bucket in 

place during shipping. 

 

Do not re-attach the rain collector cone at this point; you will need to test the 
tipping bucket before you complete the installation.

 

5. Apply power to the station console.

 

To power up the console, first remove the console’s mounting base by press-
ing down on the large tab between the two oblong holes on the base’s 
underside and pulling the base free. Plug the power adapter into the center 
“Power” slot, as shown below, and then plug the other end into a 110 VAC 
outlet. Once power is applied, the console should beep twice within 10 sec-
onds if the console is working properly. (If you have the optional Weather-
Link installed, the console should beep three times within 20 seconds.) The 
readings will appear dashed out until you connect the sensors.

 

Note:

 

If you are going to use a battery as backup, make sure that you plug in the AC power before 
installing the battery. Powering up the console with the battery alone may cause the console 
to lock up due to insufficient power. (Do NOT use a backup battery if you use the optional 

 

EZ-Solar Power Kit.)

Twist off the rain collector cone.

Snip the black cable tie.

Console

Base

Power Adapter

AC Power

Outlet

Summary of Contents for Energy EnviroMonitor

Page 1: ...dard and industrial The industrial option offers greater protection from radio frequency interference electrostatic discharges and voltage surges by provid ing 100 feet of shielded cable an extra grou...

Page 2: ...ctor Cone EZ Sensor Arm Additional Components for INDUSTRIAL Installations Only ICAM Kit 8 Conductor Cable Standard for ICAM to Console 25 7 5m 16 5 5m Ground Wire 6x1 25mm Screws Cable Ties Adhesive...

Page 3: ...the extension tube page 4 Attach the anemometer page 4 Attach the wind cups page 4 Snip the cable tie in the rain collector page 5 Apply power to the console page 5 Attach the EZ Sensor Arm page 6 Con...

Page 4: ...s positioned over the white field case and NOT over the black rain collec tor cone 3 Attach the wind cups to the anemometer Push the wind cups onto the shaft as far as they will go then tighten the se...

Page 5: ...rge tab between the two oblong holes on the base s underside and pulling the base free Plug the power adapter into the center Power slot as shown below and then plug the other end into a 110 VAC outle...

Page 6: ...port tube insert the EZ Sensor Arm letting the wire drop through the bottom gap in the brace clamp and tighten Alternative EZ Sensor Arm Positioning You may face the sensors straight up as shown above...

Page 7: ...ere Note This alternative configuration is not standard for meteorological measurements Use the following rubric to determine the tilt angle for maximum readings Maximum Readings During Spring or Fall...

Page 8: ...d release the lever d Connect the bare drain wire to the SHIELD terminal JP2 and cut off any excess drain wire e Attach the ground wire to the SHIELD terminal JP2 as well Run the ground wire and the s...

Page 9: ...in the sensor array field case keeping in mind that you will need a power source you should locate the console indoors For more accurate readings follow these suggestions Avoid placing console in dir...

Page 10: ...the station facing a different direction see Recali brating the Wind Vane on page 12 for instructions on how to adjust the wind vane accord ingly Note For roof mounting we recommend the optional Mount...

Page 11: ...ble underneath the eaves of your house or in another location similarly shielded from rain place cable clips or weather resistant cable ties approximately every 3 5 feet 1 1 6 m Note Do not use metal...

Page 12: ...compass or local area map to determine which direction N S E W NE etc the anemometer arm is pointing 4 Use the wind direction chart to find the degree reading which corresponds to that direction 5 Sl...

Page 13: ...ON A SHELF Or to display the console on a wall follow these steps a Hold the mounting base flat against the wall and use a pencil to mark the location of the two keyholes b Use an electric drill with...

Page 14: ...AC DC power cord and listen for 2 beeps within 10 seconds Note If you have the WeatherLink installed listen for 3 beeps within 20 seconds and then if all is well try communicating with the WeatherLink...

Page 15: ...ly with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installati...

Page 16: ...iroMonitor and Health EnviroMonitor Systems Rev A Manual 7 8 99 Controlled online Weather Manuals Consoles EZ EZ Adv This product complies with the essential protection requirements of the EC EMC Dire...

Reviews: