background image

STATION

DIAGNOSTICS

To receive from a different transmitting station:

1. To enter the setup screen, press and hold 

 DONE 

 and then press 

−−

 

).

2. In the first setup message, you will see RECEIVING FROM. Wait a few mo-

ments until all the available station IDs are displayed.

3. Press 

 DONE 

 to advance to the next setup message (station 1).

4. Press 

( + )

 or 

−−

 )

 to set the station ON (to receive from that station) or OFF (to

not receive).

5. Press 

 GRAPH 

 to change the station type: ISS, TEMP, HUM, TEMP HUM,

WIND, RAIN, LEAF, SOIL, SENSORLINK.

6. Press 

 STATION 

 to advance to the next station ID.

7. Repeat steps 4–6 to set multiple stations.
8. Press and hold 

 DONE 

 to return to the current weather screen.

To retransmit data to another wireless console:

1. To enter the setup screen, press and hold 

 DONE 

 and then press 

−−

 

)

.

2. Press 

 DONE 

 twice to advance to the RETRANSMIT setup message.

3. Press 

( + )

 or 

−−

 ) 

to set the retransmit capability ON or OFF.

4. Press 

 STATION 

 to advance to the next station ID.

5. Press and hold 

 DONE 

 to return to the current weather screen.

The diagnostic screen

 is used by our tech support staff to help

diagnose problems. If you are experiencing difficulties, call us at 

(510)

732 7814

, Monday through Friday, 7:00 a.m. to 5:30 p.m., Pacific Time.

To check reception and/or change antenna gain:

1. To enter the diagnostic screen, press and hold

  TEMP  

and then

press

  TIME 

. You will see GAIN ON or GAIN OFF in the ticker tape.

2. Look for the number with the % sign in the middle of the top row. A

number >= 90% is good or excellent. If the number you see is < 90%,
try changing the gain or relocating the console. Sometimes moving
the console just a few feet can make a big difference.

3. To change the antenna gain, press

  HI/LOW

. Set GAIN OFF if there

are multiple transmitters (including cordless phones or baby moni-
tors) in the area. Set GAIN ON if the transmitter and the console are
far apart from each other or there are physical barriers (such as
trees, walls, or large appliances) between them.

4. To exit the diagnostic screen, press 

 DONE 

.

26

7

SET

ALARM

To set an alarm:

1) Press 

 2

ND

 

 &

 

 

ALARM

  to enter the alarm screen. The        icon will

appear on the screen. In each field, you will either see the alarm set-
ting or, if no alarm has been set, a series of dashes.

2) Press 

 TIME 

 or a weather variable key, or use 

( + ),

 

( – )

( < )

, or 

( > )

to move between weather variables. Except for the time alarm, the
graph icon will move to show you which variable you have selected.

3) Press 

 HI/LOW 

 to switch between high and low alarms. Not all

alarms are available for all weather variables. See 

Console Manual

for details.

4) Press

  2

ND

  

 SET 

 to enter or change an alarm setting. Use 

( + ) 

or

( – )

 to change the digit within a field. Use 

( < )

 or 

( > )

 to move to the

next field.

5) Press 

 DONE 

 to accept the alarm setting. Repeat steps 2–4 to set

another alarm, or press 

 DONE 

 again to exit the alarm screen.

The 

 SET 

 

key is also used

 to enter selected daily, monthly, and

yearly totals and to calibrate selected readings. See 

Console Manual

 for

details.

To set an alarm: 

See "SET." (NOTE: Not all alarms are available for

all weather variables. See 

Console Manual

 for details.)

When an alarm is triggered, you will hear an audible alarm:

 Until conditions change (i.e., they rise above or fall below the alarm

thresholds you have set) or you clear the alarm, if the console is being
run on AC power.

 For two minutes, if the console is being run on battery power.

 For one minute, if you have set a time alarm.

And you will see visible alarms:

 The alarm bell icon will blink on and off.

 A message will appear in the ticker tape.

To silence an alarm: 

Press 

 DONE 

.

To clear all alarm settings:

 Press 

 2

ND

 

 &

 

 

ALARM

  to enter the

alarm screen. Press 

2

ND

 

 and then press and hold  

ALARM

  until

dashes appear in all the fields. Press 

 DONE 

 to exit the alarm screen.

To clear individual alarm settings:

 See “CLEAR.”

24

9

RAIN DAY

CHILL

Press

  2

ND

  

 RAIN DAY  

to toggle between:

 Rain Day (0.00 in, 0.0 mm)

 Rain Storm (0.00 in, 0.0 mm).

Press

 

 2

ND

 

 & 

 UNITS 

 

to change unit of measure.

All rain and ET readings will read in the same unit of measure. Chang-
ing one from 0.00 inches to 0.0 mm (or vice versa) changes all others.

To view the last 24 rain storms:

1. Select Rain Storm, then press 

 GRAPH 

 to enter the graph screen.

2. Press 

( < )

 or 

( > )

 to move backward or forward in time.

3. Press 

 DONE 

 to exit the graph screen.

On the ticker tape:

LAST 24 HRS OF RAIN . . . will appear on the ticker tape if it has rained
within the last 24 hours and you are currently displaying rain rate.

STORM STARTED ON . . . will appear when you are displaying rain
storm.

Press

  2

ND

  

 CHILL  

to display:

 Wind Chill (

°

F, 

°

C)

Press

 

 2

ND

 

 & 

 UNITS 

 

to change unit of measure.

All temperature-related readings (inside and outside temperature, wind
chill, heat index, and dew point) will read in the same unit of measure.
Changing one from 

°

F to 

°

C (or vice versa) changes all others.

On the ticker tape:

WIND CHILL WARNING . . . will appear on the ticker tape when you are
displaying wind chill if the reading is <0

°

F (

18

°

C) and the 10-minute

average wind speed is >=10 mph (16 km/h).