background image

 

H

 

A R D W A R E

 

  I

 

N S T A L L A T I O N

 

Typical Direct Connection

 

5

 

T

 

Y P I C A L

 

  D

 

I R E C T

 

  C

 

O N N E C T I O N

 

The instructions below explain how to make a typical direct connection. Note that 
if you extend the cable run beyond 48' (14.4 m), the software may have difficulty 
communicating with the station.

 

T

 

YPICAL

 

 D

 

IRECT

 

 C

 

ONNECTION

 

Direct Connection Installation

 

1. Enter the console’s Setup Mode by pressing and holding the DONE key, then pressing 

the “DOWN arrow” key. 

 

Entering Setup Mode ensures that the station is not writing any data and 
saves the current daily totals, highs, and lows to memory.

 

2. Remove the battery cover from the console back and remove all power by removing 

the batteries and AC-power adapter, if present.

 

Failure to remove power to the console before installing the data logger may 
cause damage to the data logger or console.

 

3. Carefully insert the data logger into the large receptacle jack marked 

 

EXPANSION

 

 

inside the battery compartment

 

Guide the data logger cable through the square slot below the receptacle.

 

CAUTION:

 

 Make sure that whenever you connect or disconnect the logger from the console that 

the console is NOT powered up. Plugging or unplugging the data logger while power 
is applied can lock up or damage the logger.

 

4. Restore power to the weather station by reinstalling the batteries and reattaching the 

power adapter, if present.

 

The weather station should beep three times; each beep should occur within 
about one second of the others. 

 

5. Replace the battery cover, ensuring that the data logger cable exits through the square 

slot.

Vantage Pro console

data logger

8' (2.5 m)

data logger

cable 

COM Ports

Optional 40' (12 m) 4-Conductor

 Extension Cable and Coupler

Connection

Options

(DB-9)

9-pin connector

battery cover

Summary of Contents for and Vantage Pro

Page 1: ...Getting Started Guide WeatherLink Vantage ProTM Product 6510 For...

Page 2: ...r more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from...

Page 3: ...ct Davis Instruments technical support at 510 732 7814 Loopback connector The loopback connector is a short piece of cable with a phone plug at one end and a red plastic cap at the other The loopback...

Page 4: ...ry for the data files depends on the archive inter val Database files containing data stored at a 30 minute archive interval require approximately 36K of disk space per month of data The file size cha...

Page 5: ...logger may cause damage to the data logger or console 3 Carefully insert the data logger into the large receptacle jack marked EXPANSION inside the battery compartment Guide the data logger cable thro...

Page 6: ...eatherLink s bul letin summary or real time strip charts if the console is attached to the computer 8 Check the Baud rate settings on the console Enter the console SETUP mode by pressing and holding t...

Page 7: ...he battery cover from the console back and remove all power by removing the batteries and AC power adapter if present Failure to remove power to the console before installing the data logger may cause...

Page 8: ...have to turn the console on and off again A Few Notes About Phone Modem Connections If you indicate a phone modem connection when setting up your station the soft ware automatically dials the station...

Page 9: ...with your station you must add your station to WeatherLink s database which means naming the station configuring the software to work with that station and with your computer hardware and setting stat...

Page 10: ...Set Barometer Elevation Set the barometric pressure and your elevation on the station and on the soft ware Set Rain Calibration Set the station s rainfall calibration number Set Temperature and Humid...

Page 11: ...ocedure for locating the serial port to which your sta tion is connected or determining whether that serial port is working Using the Loopback command as opposed to Test will help you find the correct...

Page 12: ...d serial ports and inform you of the COM port at which the loopback connector is located The software automatically selects the correct COM port for you in the Serial Port dialog box If it cannot find...

Page 13: ...he first beep tells you the processor is running The second beep will be for the logger if installed and the third beep is for the display If you do not hear one or more of these beeps contact Davis I...

Page 14: ...e time and date on the weather station are correct I have duplicate records in my database Why If you do not download from the data logger prior to changing the weather station s time and date for a D...

Page 15: ...ower to the sta tion Note Make sure to put the console in Setup Mode by pressing the DONE and DOWN arrow keys before removing the batteries The ensures the station will not try to write any data when...

Page 16: ...lose Window F1 Context Sensitive Help F2 Sunrise Sunset Report F7 NOAA This Month F8 NOAA This Year Strip Chart Window ESC Halt redraw Ctrl M Make Default Ctrl P Print Strip Chart F1 Context Sensitive...