Troubleshooting, Repair, & Warranty
Page 48
Vantage Pro Manual
H
UMIDITY
Inside humidity seems
too high or too low
Make sure the console is not near a
humidifier or de-humidifier.
Check calibration number and adjust if
necessary.
If inside humidity is low, and inside tem-
perature is too high, see “inside temp”
above.
14
33
W
IND
S
PEED
Wind speed reading
seems too high or too
low.
Check installation by spinning wind cups.
If it’s too low, remove the wind cups and
check for friction sources. See ISS manual.
Check ISS location. Is it sheltered from the
wind?
Wind speed reads 0
either all the time or
intermittently
The problem may be with the anemome-
ter. Check fields one-b and two-b on diag-
nostic screen. May require call to tech
support.
49
D
IRECTION
Wind direction reading
is dashed out
Wireless model - check reception. See
Reception Problems below.
Cabled model - cable may be faulty.
If these steps do not reveal the problem,
the anemometer may be faulty. Call the
factory for return authorization.
49
Wind direction always
says North
ISS problem, especially if outside tempera-
ture is dashed out as well.
CHILL
Wind chill reading
seems too high or too
low
Check calibration numbers for tempera-
ture and wind speed. Remember, wind
chill depends on temperature and wind
speed. Make sure they’re working.
33
Problem
Solution
PG.
Summary of Contents for and Vantage Pro
Page 6: ...Page 6 Vantage Pro Console Manual ...
Page 10: ...Welcome to Vantage Pro Page 10 Vantage Pro Console Manual ...
Page 16: ...Console Installation Page 16 Vantage Pro Manual ...
Page 18: ...Console Installation Page 18 Vantage Pro Manual ...
Page 44: ...Using the Console Page 44 Vantage Pro Console Manual ...
Page 63: ...Vantage Pro Manual Page 63 ...