background image

12

1. Install the sensor in the environment per the 

manufacturer’s instructions, making sure the 
sensor is installed within cable reach of the Node 
when it is mounted.

2. On your smartphone, open the EnviroMonitor 

app and select this Node. Tap 

Add Sensor

. From 

the menu, first select the sensor type, then the 
specific sensor. Follow the wiring diagram in the 
app to correctly wire the sensor into one of the 
green 6-wire sensor connectors. Using a 2.5mm 
(3/32”) precision slotted screwdriver, loosen the 
appropriate screws and insert the bare wires. 

3. Tighten the screws very tight.
4. Insert the 6-wire sensor connector into the sensor port indicated by the app. 

Make sure it is aligned properly and not offset.

Note: 

If the Davis sensor has an RJ-plug on its 
cable, use the Davis RJ Adapter, product 
number 6860. Or, you can remove the 
plug and strip the wires. 

Try not to strip the covering back so far 
that the bare wires can touch each other 
when the connector is plugged in, but make sure the clamp in the sensor port is 
closing on wire, not plastic. (About 1/4” [6.4 mm] of exposed wire is ideal.)

5. Run the sensor cable down and 

out of the box through the 
bottom. 

Make sure it will be 

enclosed by the foam when 
the Node door is closed.

6. When all sensors are installed, 

close the Node door, making 
sure all cables are against the 
foam and not the hard plastic 
of the door. Use included zip 
ties and adhesive mounts if 
desired.

1

2

3

4

6

5

Wire each 
sensor as
directed in 
the App

RJ Adapter, 
#6860

Make sure
cables exit 
against
the foam.

Adhesive
Mount

Foam

Note: Make sure none of the 
sensor cables are pinched in 
the door; 

especially

 the cable 

on the the sensor installed in 
Port 1.

Summary of Contents for EnviroMonitor 6805

Page 1: ...Product numbers 6805 and 6810 USER MANUAL IP Gateway and Node 3465 Diablo Avenue Hayward CA 94545 2778 USA 510 732 9229 www davisinstruments com...

Page 2: ...used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co located or operating in conjunction with any other antenna or transm...

Page 3: ...tor Gateway and Nodes If you are just installing a Node and have already installed the Gateway you can skip to page 9 Set Up Nodes and Sensors Note Your IP Gateway is designed to be installed either i...

Page 4: ...higher they are mounted the longer the transmission distance The Gateway should be placed in a window or as close to the outside of the building and as close to the Nodes as possible higher is better...

Page 5: ...s should go Note If you are mounting the IP Gateway outside enclose it in a Universal Shelter product number 6618 SAMPLE FARM Vegetables Almonds East Almonds West Peppers H w y 1 0 Davis Rd Strawberri...

Page 6: ...of either two or more other Nodes or the Gateway and another Node A Node can even be installed simply to transmit data from more distant Nodes to the Gateway without any sensors installed in it By pl...

Page 7: ...quirements Tools Wi Fi or router Ethernet internet connection Wi Fi password Smartphone 4 AA batteries not included IP Gateway AC Adapter Blue LED Recessed Touch Pad External Antenna Connector Etherne...

Page 8: ...or app will guide you through creating an account on WeatherLink com adding the Gateway adding Nodes to the Gateway and adding sensors to the Node EnviroMonitor App EnviroMonitor App Guides you throug...

Page 9: ...r database on the WeatherLink cloud 2 Install the batteries Open the battery compartment on the bottom of the Gateway To do this slide the cover forward then lift up Insert four AA batteries making su...

Page 10: ...touch pad For the location of the recessed touch pad see the illustration on page 5 Contents of Gateway 6 The LED will turn solid blue when the Gateway has successfully connected to your smartphone 7...

Page 11: ...Panel Cable Mesh status LED Bluetooth status LED Solar Panel Jack Sensor Ports Internal Mesh Antenna Lithium Battery Battery Compartment Door Door Tabs Connector for Internal or External Antenna 1 4...

Page 12: ...en working outward to the Node furthest from Gateway This allows each Node to establish a connection with the Gateway or a Node that has already been installed Power up and Connect the Node Make sure...

Page 13: ...ifying information to the Node and allows its data to be received by the Gateway Having specific identification for each Gateway Node pair allows you to have multiple Gateways without cross transmissi...

Page 14: ...an RJ plug on its cable use the Davis RJ Adapter product number 6860 Or you can remove the plug and strip the wires Try not to strip the covering back so far that the bare wires can touch each other w...

Page 15: ...Hemisphere or north in the Southern Hemisphere Tip Mounting the Node may be easier if done by two people Mounting On a Fence Post or Pole Mount the Node onto a fence post or a pole with an outside di...

Page 16: ...range from Node to Gateway or Node to Node you may replace the internal mesh antenna with an external Long Range Antenna See page 17 Appendix A Using an External Long Range Antenna Manage Your Data Lo...

Page 17: ...are aligned properly and not offset Make sure the screws on the sensor adapters are very tight Make sure none of the sensor cables are pinched in the Node door If these steps don t solve the problem...

Page 18: ...Radio LED The radio LED has timed out to save power Close then open the door to activate the radio LED Radio LED is solid amber for 3 seconds when powering up The Node is powering up Radio LED is blin...

Page 19: ...on ranges of each of the antennas The antenna that comes installed in your Gateway or Node is a standard dipole If you need a longer cable for installation of the antenna use an Antenna Extension Cabl...

Page 20: ...a to seal the hole Then follow the steps below 1 Screw the antenna cable into the connector on the side of the IP Gateway 2 Use the EnviroMonitor app on your smartphone to set up the antenna In the ap...

Page 21: ...over tighten 4 Run the cable out the bottom of the Node making sure it exits against the foam 5 Close the Node shelter 6 Mount the antenna on a pole as high as possible using the mounting hardware inc...

Page 22: ...product number 7692 025 To use the extension cable 1 Loosen the end caps of the weatherproof junction cover and insert the extension cable through the cover 2 Connect the extension cable to the anten...

Page 23: ...o 4670 m Update Interval 1 minute Weather Station Wireless Communications Range Line of Sight up to 1000 feet 300 m Through Walls 200 to 400 feet 60 to 120 m Node Operating Temperature 4 to 140 F 20 t...

Page 24: ...is ISO 9001 certified 3465 Diablo Avenue Hayward CA 94545 2778 U S A 510 732 9229 Fax 510 732 9188 info davisinstruments com www davisinstruments com Contacting Davis Technical Support For questions a...

Reviews: