WeatherLInk Live
™
Product Number 6100
Document Number: 07395.356 Rev. B 4/16/19
Vantage Pro
®
, Vantage Pro2
™
, Vantage Vue
®
, and WeatherLink
®
are trademarks of Davis Instruments
Corp., Hayward, CA.
© Davis Instruments Corp. 2019. All rights reserved.
Information in this document subject to change without notice. Davis Instruments Quality Management
System is ISO 9001 certified.
3465 Diablo Avenue, Hayward, CA 94545-2778 U.S.A.
510-732-9229 • Fax: 510-732-9188
®
info@davisinstruments.com • www.davisinstruments.com
Contacting Davis Technical Support
For questions about installing or operating your WeatherLink Live, please contact
Davis Technical Support. We’ll be glad to help.
Specifications
(See www.davisinstruments.com for more information)
Operating Temperature . . . . . . . . . . . . . . . . . 32° to +140°F; 0° to +60°C
Current Draw . . . . . . . . . . . . . . . . . . . . . . . . . Average: 100 mA; Peak 700mA
Housing Material . . . . . . . . . . . . . . . . . . . . . . Rugged ABS Plastic
Backup Batteries . . . . . . . . . . . . . . . . . . . . . . 4 AA (not included)
Battery Life . . . . . . . . . . . . . . . . . . . . . . . . . . 5 days
AC Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . 5 VDC, 1000 mA
Wi-Fi Band. . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4 GHz 802.11b/g/n
Sensor Data (internal sensors)
Barometric Pressure
Resolution and Units . . . . . . . . . . . . . . . 0.01" Hg, 0.1 mm, 0.1 hPa, 0.1mb. (user selectable)
Range. . . . . . . . . . . . . . . . . . . . . . . . . . . 16.00" to 32.50" Hg, 410 to 820 mm Hg,
540 to 1100 hPa or mb
Elevation Range. . . . . . . . . . . . . . . . . . . -1500' to +15,300' (-460 m to 4670 m)
Update Interval . . . . . . . . . . . . . . . . . . . 1 minute
Inside Relative Humidity
Resolution and Units . . . . . . . . . . . . . . . 0.1%
Range & Accuracy . . . . . . . . . . . . . . . . . 1 to 100% RH; ±2%
Accuracy. . . . . . . . . . . . . . . . . . . . . . . . . ±2%
Update Interval. . . . . . . . . . . . . . . . . . . . 1 minute
Inside Temperature
Resolution and Units . . . . . . . . . . . . . . . Current Data: 0.1°
Range. . . . . . . . . . . . . . . . . . . . . . . . . . . +32° to +140°F (0° to +60°C)
Sensor Accuracy. . . . . . . . . . . . . . . . . . . ±0.5°F (±0.3°C) (typical)
Update Interval . . . . . . . . . . . . . . . . . . . 1 minute
Weather Station Wireless Communications
ID Codes Available . . . . . . . . . . . . . . . . 8
Range
Line-of-Sight . . . . . . . . . . . . . . . . . . . up to 1000 feet (300 m)
Through Walls . . . . . . . . . . . . . . . . . 200 to 400 feet (60 to 120 m)
Online
www.davisinstruments.com
See the Weather Support section for copies of user
manuals, product specifications, application notes,
software updates, and more.
support@davisinstruments.com
Telephone
(510) 732-7814
Monday - Friday, 7:00 a.m. - 5:30 p.m. Pacific Time.