Station Configure

 

 
Before setting alarms, use this function to indicate what sensors you have 
with your Vantage Pro or Vantage Pro2 system.  The Configuration Utility 
uses your choices to determine what parameters to show in the list.  Note 
that you can only enter this dialog box when no alarms are set.  This 
prevents a user from hiding a parameter that is set as an alarm condition. 
 

 

 
Selecting Vantage Pro Plus automatically checks the Solar Radiation and UV 
check boxes.  You can also check them separately. 
 
The Leaf Wetness, Soil Moisture, Leaf Temperature, and Soil Temperature 
selections refer to the sensors on the Leaf & Soil Moisture Temperature 
Station or Soil Moisture/Temperature Station.  Temp 1, Temp 2, Humidity 1, 
Humidity 2 refer to the sensors on the Wireless Temperature or Wireless 
Temperature/Humidity Stations.  Indicate the sensor by selecting the number 
that corresponds to the transmitter ID on your Wireless Temperature or 
Temperature/Humidity Station.  Please note that the Alarm Output data 
logger makes no distinction between Vantage Pro and Vantage Pro2. 
 

5

Summary of Contents for WeatherLink

Page 1: ...d Guide and on line Help files for information on the use of the WeatherLink program including its hardware requirements and typical installation package contents and optional accessories for this pro...

Page 2: ...as WeatherLink if you ever need to install the program manually Running the Configuration Software To run the configuration software double click on the Streaming Data Utility icon in the Streaming Da...

Page 3: ...ata logger connected to your system it is highly recommended that you manually set the Com Port and Baud Rate Logger Type The software indicates the logger type and firmware revision level of the stre...

Page 4: ...ave an output open or closed You may adjust this value if you want the alarm checking functions to resume later after communicating to the logger using WeatherLink or the Streaming Data Utility Press...

Page 5: ...olar Radiation and UV check boxes You can also check them separately The Leaf Wetness Soil Moisture Leaf Temperature and Soil Temperature selections refer to the sensors on the Leaf Soil Moisture Temp...

Page 6: ...smitter ID 1 and a Temperature Humidity Station on ID 4 and a Temperature Station on ID 2 you would check the following dialog boxes in the example shown below There is no need to indicate your ISS Te...

Page 7: ...ts of measure displayed on the console which may be changed independently of this software You may select from the following settings Temperature Fahrenheit F or Celsius C Note Wind chill dewpoint deg...

Page 8: ...rical device This function is used to test the output of the Alarm Output data logger Push the button of the output you want to test The button will be depressed to indicate Closed circuit mode and ra...

Page 9: ...directory When download is complete the text file will automatically open The log will consist of which output became active which parameters caused the alarm to become active useful for the AND type...

Page 10: ...it is deactivated The default value is zero Frequent communication with the data logger will cause this function to run long Pulse Width This function determines the pulse width for any of this selec...

Page 11: ...utput data logger to leave an electrical device OFF unless an alarm condition occurs Choose normally closed if you want the Alarm Output data logger to leave an electrical device ON unless an alarm co...

Page 12: ...Then select what type of test condition you want to check it against A Greater Than or or high alarm checks for greater than or equal to A Less Than or or low alarm checks for less than or equal to 12...

Page 13: ...A Between alarm checks to see if the current value is between the two threshold values A Not Between alarm checks to see if the current value is not between the two threshold values 13...

Page 14: ...g a value of concern It is like a predictive alarm If the number you enter in the first edit box is lower than the number you enter in the second box the data logger will check for an upward trend Lik...

Page 15: ...aching a value of concern Make note of how quickly the value changes over time before it reaches that value These changes will govern your threshold values and time period Your second threshold probab...

Page 16: ...F Inside Temperature Minus Outside Temperature IS Greater Than or 5 0 F AND Inside Temperature IS Greater Than or 70 F DONE 2 A user wants to activate their sprinkler system when the Daily ET exceeds...

Page 17: ...onditions Choose DONE if this is the only condition you want to check Choose OR if you want this condition or any of the other conditions you set to trigger an alarm Choose AND if you require this con...

Page 18: ...be powered for at least 10 minutes to utilize a valid wind chill value Dewpoint formula is also the same as what the Vantage Pro and Vantage Pro2 console uses but this has not changed from the origina...

Page 19: ...e device it is not subject to arcing and contact welding as are mechanical relays However since it is a solid state device it will be damaged by operation beyond its ratings which are Nominal Load Vol...

Page 20: ...Product Number 06544 Davis Instruments Part Number 07395 219 WeatherLink for Alarm Output Rev A Addendum 08 30 05...

Reviews: