500224R07
DAVISCOMMS (S) PTE LTD
Daviscomms Confidential
- 31 -
Calibration process by Serial Port
Step 1:
▪
Connect the RS232 to the PC, with Hyperterminal set as below;
Bits per sec:
115200
Data bits:
8
Parity:
none
Stop bits:
1
Flow control: none
Step 2:
▪
Long press the “reset” button for >3sec to enter calibration mode
Step 3:
▪
Use the command (AT$MZ) to start the calibration.
Fig. (3) Shows the examples of calibration results on Hyperterminal.
SMS to EaziTRAC 1000
SIM card No.
Response from EaziTRAC 1000
Calibration result (data can be varied)