1
The pressure value is
always very small or
zero.
1.1
The tubes are bending or breaking
Check the tubes and connection
1.2
The connection between the sensor
and transmitter is not firm
Check the electrical connection of
the sensor module
1.3
The pressure sensor got a problem
or the transmitter got a problem.
Please consult the manufacturer for
a warranty or replacement.
2
From system: HW_Error
= 1
2.1
The lost connection between the
sensor and the transmitter
Check the electrical connection of
the sensor module
2.2
The sensor module got a problem.
Please consult the manufacturer for
a warranty or replacement.
There are no moving parts or consumed parts in the ULP Sensor. Therefore there is no need to do maintenance.
However, the pressure sensor will drift over time. We do recommend customer to re-calibrate it every 12 months.
This ULP Sensor has the default configuration. The user can change the configuration on the transmitter so that the
complete device ( transmitter) delivers the proper output values. Below are some configuration parameters
stored in the transmitter's flash memory.
Description
Unit
Default Format Property
Comment
CONSTANT_A
1
Float
R/W
Constant a for scaling pressure value (in Pa)
CONSTANT_B
0
Float
R/W
Constant b for scaling pressure value (in Pa)
HIGH_CUT
1E+09
Float
R/W
High cut value for scaled value
LOW_CUT
0
Float
R/W
Low cut value for scaled value
SENSOR_BOOT_TIME
mS
200
Uint32
R/W
Boot time of sensor/input, in ms
TEMPERATURE_OFFSET_X10
oC
0
int16
R/W
Offset adjustment for measured temperature
value
END.
7. Maintenance of the ULP Sensor
8. Default configuration
Summary of Contents for Lidar People Counter
Page 2: ...Daviteq Optical Sensing Technologies...
Page 8: ...Daviteq Radar Sensing Technologies...
Page 9: ...Daviteq Gas Detection Technologies...
Page 27: ......
Page 34: ......
Page 38: ...C m u n i M12 v o c m bi n Si t ch t k t n i M12...
Page 43: ...Daviteq Electrical Sensing Technologies...
Page 51: ...Daviteq Ultrasonic Level Distance Measuring Technologies...
Page 57: ...Thermal mass flow Pitot tube Orifice plate Daviteq Air Gas Flow Measurement Technologies...
Page 64: ...Figure 12 Adjust the orientation of the probe 5 7 Attach the Wireless Transmitter to the probe...
Page 67: ...Daviteq Inertial Measurement Technologies...
Page 80: ...Daviteq Pressure Measurement Technologies...
Page 87: ...Tel 84 28 6268 2523 4 ext 122 Email info daviteq com www daviteq com...