DV-302 OPERATION MANUAL
14
4.2.8 LED Status
When DV-302 is turned on, you can easily observe the current operation status of
the system using LEDs located on the product.
TABLE 6. LED STATUS
LED STATUS
SYSTEM STATUS
PWR LED
Light ON
When power is present (POWER ON).
STS LED
Blink rapidly
After power on, light OFF for 10 seconds
Light OFF
For the image loading time. About 15 seconds
Blink per 0.25 sec
IP Address assignment is completed
But Registration is still on progress.
Blink per 1 sec
VOIP registration is completed successfully
NET LED
Light ON
Connected physically
Light OFF
Lost Physical WAN connection
Blink
Data is being transferred over the connection
PC LED
Light ON
Connected physically
Light OFF
Lost Physical LAN connection
Blink
Data is being transferred over the connection
TEL LED
Light ON
In-USE (Off-hook)
Light OFF
Not in-USE (On-hook)
Blink
Ringing (according to Ring cadence)
Voice Message Waiting Indication
If there is no LED light, check the power cable connection or external adapter.
Device will be restarted when you push the <
DEFAULT
> button shortly at the
rear of DV-302
When pushing the <
DEFAULT
> button about 4-5 sec, factory default settings will
be reloaded; the power LED will be ON and STS LED will be OFF.
NOTE
STS LED is blinking per 1 second even though one of TEL port is not
registered.