Seasonal Shutdown
To prevent damage when dispenser is exposed to freezing temperatures, water must be drained.
1. Unplug dispenser tank from power supply.
2. Turn thermostat control dial to lowest position (fully counterclockwise).
3. Turn faucet on and run water until water is cold.
4. Place a 3-quart (2.8 L) container under drain plug at bottom of the tank. Use a screwdriver to remove the screw and O-
ring in the drain tube opening. When tank is fully drained replace O-ring and screw. Tighten to reseal the drain.
CLEANING AND MAINTENANCE
Cleaning Quick-Connect Filter Screen at Cold Water Inlet
If you notice that the water flow is reduced, it may be necessary to clean the
quick-connect screen, Refer to Installation Step 4.
1.
Check heater is out of auto running mode. Turn on faucet and run water until
it is cold to avoid possibility of burn.
2.
Release cap with a screwdriver, pry it loose using the notch in the cap.
3.
Also using the screwdriver push in on the smallest ring around copper line.
This action releases tension, allowing disconnection of the copper line and
quick-connect.
4.
Pull cone shaped filter screen out (there will be slight tension) and clean with
vinegar as necessary. Check cap and clean as necessary. If deposits have
hardened, soak in vinegar for an hour or two. Then use a brush to clean.
5.
Reassemble in reverse order of disassembly. Be aware, when inserting the
screen back into place there is a slight resistance. Push until the screen "pops"
into place. Check for leaks.
6.
Check heater to go in the auto running mode. The dispenser will be ready in
about 15 minutes.
NOTE :
Do not plug appliance into power supply if tank is empty.
O-ring
screw
QUICK-CONNECT FITTING
WITH FILTER AND CAP
cap
notch
filter
26