2 GENERAL INFORMATION

 

 

2.1 General Information 

 
 
-The user manual which is given with condensing 
boiler is inseparable piece of the device.  Because 
of this, it must be kept carefully and it must be 
kept in a place near the device that is immediately 
got. In case of any lost or damage, it must be 
supplied from DAXOM Company. 

 

 
Any person except authorized person or person 
who had education from authorized service must 
not interfere to device. 

 

Considering warnings inside the manual is 
important for both your safety and safe operation 
of the device.  
 
Device must be operated by installing stated inside 
the manual under necessary conditions of safety 
and operating. Under these conditions DAXOM 
trade mark boiler is less than 2 years warranty 
cover by Manufacturer Company.  
 
Using the device out of its purpose, using different 
from conditions stated inside the manual, interfere 
by unauthorized person and problems which cause 
because of external factors such as (gas, electric 
and etc) are evaluated as out of warranty. 
 
The lifetime of the device determined by Ministry 
of Customs and Trade is 10 years in case of obey to 
user instructions. In the meantime manufacturer 
and Seller Company obliged to meet service and 
spare parts of user. 
 
The first operation and controls of boiler must be 
done by authorized service and product guarantee 
must be done. Devices which are using before 
doing warranty start by authorized service will be 
no warrantable.  

2.2 Giving Information to 
Customer While Deliver the Device 

Tell consumer about operation of the device, 
significant points that must be careful before 
operation of the system or during operation of 
system, importance of periodic maintenance in 

terms of performance and efficiency of device and 
inform about maintenance agreement.  
 
Explain user that necessary services contact 
information is found inside user manual. 

 

Deliver the user manual to consumer and tell him / 
her that are needed to keep near the boiler.  
 

2.3 Description 

 
DAXOM Navidens boilers are condensing boilers 
that are used by installing wall are designed as 
heating water inside heating system  with NG or 
LPG and also meet the need  heat demand of a 
boiler through this water.    
 
DAXOM Navidens condensing boilers are also 
enable for coupled solar energy to boiler system. 
On the other hand, they have necessary 
substructure for heating swimming pools. 
 
There is burner inside the boiler which provides 
Combustion with aluminum casting hot bulb and 
premix technology. 
 
There is flow meter gas valve on the boiler which 
determines and stops quantity of gas that obtains 
necessary energy for heating. There are sensors at 
the system for following inlet and outlet water 
temperatures for the aim of determination of 
boiler operation capacity. 
 
On the other hand, for the aim of security control 
of the system there are bottom water pressure 
control wind pressure switch, drain valve, safety 
thermostat and pipe gas temperature sensor. 
Boilers’ ignition, flame monitoring, capacity 
control, safety device and operation functions 
occur by electronic control card. 
It can be operated as connected external room 
thermostat. 
By the LCD panel on the boiler information can be 
followed concerning to operation of the system. 
(Instant operation capacity, boiler inlet, outlet 
temperatures, etc) 
 

 

 

 

 

 

Summary of Contents for Navidens 50

Page 1: ......

Page 2: ...AXOM boilers provide following sufficiency Gas Appliances Directive 2009 142 EEC Boiler Efficiency Directive 92 42 ECC Electromagnetic Compability Directive 2004 108 CE Low Voltage Directive 2006 95 C...

Page 3: ...3 1 Installation 12 3 2 Plumbing 12 3 3 Natural Gas Line 12 3 4 Electrical Installation 13 3 5 Pipe Line 13 4 SAMPLE INSTALLATION DIAGRAMS 15 4 1 Heating System with Boiler 15 4 2 Cascade Heating Sys...

Page 4: ...tric supply and gas inlet of the boiler If there is freezing risk at water installation or boiler system you need to discharge water inside the plumbing Control the operation of the air conditioner of...

Page 5: ...the device significant points that must be careful before operation of the system or during operation of system importance of periodic maintenance in terms of performance and efficiency of device and...

Page 6: ...2 4 Dimension of Device Navidens 50 70...

Page 7: ...Navidens 125 145 a Safety Valve Outlet b Plumbing Return c Gas Inlet d Plumbing Exit e Condensing Outlet f Cable Entry...

Page 8: ...2 5 Boiler Installation Distances...

Page 9: ...zation Electrode 6 Ignition Electrode 7 Sight Glass 8 Combustion Space 9 Pipe Gas Temperature Sensor 10 Condensation Tank 11 Siphon 12 Electronic Control Card 13 Circulation Pump 14 Safety Valve 15 Re...

Page 10: ...Partial Load 30 C 108 107 106 85 106 08 Nominal Heat Load 80 60 C 97 97 96 12 95 94 Min Heat Load 80 60 C 95 96 94 95 Efficiency Class Pipe Dates Pipe Pressure Pa 150 135 240 210 Exhaust Gas Flow Rate...

Page 11: ...e inch 3 4 3 4 1 1 Condensing Outlet mm 30 30 30 30 Safety Discharge Outlet mm 30 30 30 30 Fresh Air Inlet mm 125 125 150 150 Exhaust Gas Outlet mm 80 80 100 100 Specifications Cascade Connections 256...

Page 12: ...ing line flows from discharge Any blockage inside condensing line causes breakdown by failure of boiler Do not forget that this condition will be evaluated as out of warranty Be sure that plumbing is...

Page 13: ...rrespond with 2 meter pipe and 45 bend correspond with 1 5m pipe Do not forget that extra connection accessories that will be used for line will also create resistance and will reduce allowed total pi...

Page 14: ...Concentric Pipe System Double Pipe System...

Page 15: ...4 Sample Installation Diagram 4 1 Heating System with Boiler...

Page 16: ...4 2 Cascade Heating Diagram with Solar Energy...

Page 17: ...stance between them C33 Vertical exit is made from roof by interwoven pipes C43 Connection to common pipe outlet by interwoven pipes C53 Exit from wall or roof with separate pipes outlets at areas tha...

Page 18: ...6 ELECTRIC PROJECT Navidens 50 70...

Page 19: ...Navidens 125 145...

Page 20: ...Pressure Switch CS Pipe Gas Sensor TL Safety Thermostat M Fan Motor P Circulation Pump CLEMENS DESCRIPTION QX2 Boiler Cycle Pump QX3 Heating Cycle Pump H5 Room Thermostat B9 Outside Environment Senso...

Page 21: ...7 ACESSORIES PRODUCT DESCRIPTION PHOTO Cascade Communication Module Three Way Valve Connection Module Outlet Air Sensor Room Thermostat Cascade Sensor...

Page 22: ...100 150 mm 45 90 Degree Bends 80 125 mm 100 125 mm Exhaust Gas Pipe 80 mm 100 mm Additional Pipe 80 125 mm 100 125 mm Fresh Air Inlet Accessory 80mm 100mm For double pipes system Exhaust Gas Outlet A...

Page 23: ...reen by ESC button after you chose AUTO your device will start to operate according to set operation hour 8 3 Room Temperature Setting While the device is in home screen turn the number 8 button Tempe...

Page 24: ...sensitively By opening hot bulb seal between burner and heat exchanger must be controlled and if it is needed it must be changed Ignition and ionization electrodes must be cleaned by emery If it is n...

Page 25: ...ceeded 6 5 Heating cycle water pressure is too low 9 Bottom water pressure limit is reduced under1 10 Change battery of outside air sensor 6 18 Heating cycle water pressure 2 is too low 9 Bottom water...

Reviews: