background image

 

Summary of Contents for Thermotank UKDAX-160GB25

Page 1: ...1...

Page 2: ...ministration EGO GDA BOTA ZGAZ etc Do not try to operate the device by yourself In case of using LPG gas do not install water heater in places below the ground level Check if product conforms to the g...

Page 3: ...3 2 GAS FIRED BOILER CONFIGURATION...

Page 4: ...Temperature o C 55 NOx Emission Class 5 Electrical Connection 220 V 50 Hz Electrical Power W 60 Electric Fuse A 2 Protection Class IP54 Height mm 1710 1960 1699 2004 2274 2274 2274 2792 2822 Diameter...

Page 5: ...uld be free from blocking preventing parts and projections during the repair and maintenance there should be sufficient space around the device for repair and maintenance Definitely flammable and expl...

Page 6: ...s inside device All connections must be tight Install the fresh air inlet pipe into the pre drilled hole as openings will stay outside and install one end of the elbow piece to the fresh air inlet on...

Page 7: ...E LENGTH m UKDAX GB25 UKDAX GB65 UKDAX GB35 TABLE 2A 80 125 80 80 100 150 100 100 90o BEND 1 1 1 1 45o BEND 0 5 0 5 0 5 0 5 UKDAX GB25 EQUIVALENT LENGTH CALCULATION TABLE Leq PIPE CONNECTION PART EQUI...

Page 8: ...suitable opening pressure safety valve at water main which is connected to cold water inlet of product There must be absolutely valve at hot water outlet line of the product Use absolutely TSE valve...

Page 9: ...9 All connections must be tight Because of acidic function of condensing water condensing water disposal must be 4 5 Condensing Connection...

Page 10: ...d to hot water outlet of product preferably nearest tap Air inside the boiler will be discharged from water faucet Turn off tap after air is discharged from tap and continious water flow After boiler...

Page 11: ...11 5 PRODUCT USAGE 5 1 Command Pannel...

Page 12: ...thorised person to product Be sure that used gas type for product is same with determined in product label Before operation of the product suitability of all connections such as pipe gas mechanic and...

Page 13: ...gas valve Hold for ON If boiler inside temperature is higher than set temperature boiler will be in standby If boiler inside temperature is lower than set temperature product starts to operate for hea...

Page 14: ...Bring the product OFF position Keep press week days start to blink By pressing or 1 second interval days are set Press button hour digit blinks 5 3 Operating Parameter Setting 5 3 1 Day and Hour Setti...

Page 15: ...rval hour is set between 0 and 23 Press min digit blinks By pressing or button one second interval min set between 0 and 60 By pressing button or if not pressing any button for a 15 sec will exit from...

Page 16: ...s Product can be used at economic mode for saving energy while using It is needed to press button for economy mode While boiler is in economy mode boiler temperature is automatically set to 45 o C and...

Page 17: ...tton When time program is activated is seen Although time program is set if it is not activated in other words if is not seen boiler does not operate according to time program For time program setting...

Page 18: ...k day days menu by pressing button Choose time program day days by pressing or button Wednesday is chosen following photo By pressing button enter hour selection menu that time program will start Choo...

Page 19: ...arting minute by pressing or button 15 is chossen at following photo By pressing button enter hour selection menu that time program will be end Choose time program end hour by pressing or button 11 is...

Page 20: ...ton 55 is chosen at following photo Time program is confirmed by pressing For selection and setting of another time programs it is needed to turn back program starting setting With explained sample ti...

Page 21: ...accidents Make sure that there is sufficient space around product Always take precautions against possible gas leakage and when the gas smell is felt shut the gas valves off urgently ventilate the env...

Page 22: ...recautions for not freezing of product at cold whethers Never touch the waste gas pipe during using and after a short time of using against skin burns In case of failure of product do not panic and st...

Page 23: ...ved magnesium anode rods lose mass The magnesium anode rod which has completely lost its mass also loses its protection feature The life of the magnesium anode rod depends on the chemical structure of...

Page 24: ...e completely Abnormal pressure Call authorised services Insufficient fresh air Make product pipe controlled Windy weather Do not use it until the wind passes Heatexchanger Block Call authorised servic...

Page 25: ...25...

Page 26: ...26...

Page 27: ...27...

Page 28: ...28...

Page 29: ...imited irketi Nam k Kemal Mah Marmara Cad No 74 mraniye stanbul Tel 90 216 369 85 36 37 Fax 90 216 385 95 45 E Mail info daxom com Merkez Servis Nam k Kemal Mah Marmara Cad No 74 mraniye stanbul Tel 9...

Reviews: