mains hot water circuit, but make sure that the water system
does not exceed 6 bars. If in doubt, have a pressure reducer
installed.
•
The area where the boiler is installed must be free of
obstructions and protrusions during repair or maintenance.
•
The electrical connection of the boiler must be made with
suitable cables, MCB/RCD and grounding must be installed.
• The wall on which your device is mounted must be strong enough
to bear the weight of the device.
The appliance must be installed exclusively on a vertical and solid
wall that can support the weight of the boiler. M8 screws with
appropriate anchors conforming to the type of the wall itself are
recommended.
Pipe of appropriate diameter to ensure adequate circulation of
the heating water must be used during installation. If the
correct diameter heating pipes are not used, constriction or
blockages in the installation may result in insufficient heating
circulation. Connections to the boiler should be easily
detachable if necessary. Non return Valves should be used
with the inlet pipes.
Separate shut-off valves should be used at
the inlet and outlet of the heating circuit. A reducer valve
should be used at the boiler cold water inlet.
5.2. Wall Mounting of the Boiler
5.2.1. Heating and Plumbing Connections
10