DG 11000PS

DG 950P

DG 5000P

DG 3800PT

DGW

DG

Installation & 

Operating Manual

Portable Petrol Generators

Summary of Contents for DG 11000PS

Page 1: ...DG 11000PS DG 950P DG 5000P DG 3800PT DGW DG Installation Operating Manual Portable Petrol Generators ...

Page 2: ......

Page 3: ...ICATIONS 1 1 2 SAFETY WARNINGS 3 CONTROLS 3 3 ELETRICAL CONNECTIONS 4 4 GENERATOR OPERATION 5 4 INDEX Davis Shirtliff Ltd 2021 Contents herein are not warranted ROUTINE MAINTENANCE 6 4 TROUBLE SHOOTING 7 5 WARRANTY 8 7 ...

Page 4: ...il alert system to stop engine in the event of low oil level not DG950P DG1200P Ÿ High capacity fuel tank for extended operation not DG950P Also available is the high specification DG4000PSi model that includes inverter technology with the following features Ÿ High specification petrol engine incorporating automatic speed control that adjusts engine speed to load leading to reduced operation fuel ...

Page 5: ...ectrical Data Alternator Brushless self exciting 2 pole Power Output 50Hz 240V single phase Voltage Regulator AVR Power Factor 1 Direct Current 12V 8 3A Speed 3000rpm GENERAL DATA Model DG950P DG1200P DG3000P DG3000E DG3800PT DG4000PSi DG5000P DG6500PT DG7500PS DG7500P DG9000PT DG11000PS Digital Multimeter Volts Hz Hours Digital Multimeter Volts Hz Hours Digital Multimeter Volts Hz Hours Digital M...

Page 6: ...use generator on a slope Fuel spillage may occur and cause a fire Do not restrict the exhaust silencer There is a danger of overheating and fire Do not connect generators together Generator damage will occur Ensure a competent trained person is used in case of overhaul 3 CONTROLS All generators are fitted with the following Ÿ 2no 3 pin AC outlets ve and ve DC connections DG950 with one outlet Ÿ En...

Page 7: ...k output voltage is 240V on the voltmeter If not adjust engine speed If the speed setting is correct and the voltage is low then the generator is overloaded and load must be reduced Ÿ If more than an appliance is connected apply load progressively with greatest load first Ÿ Close fuel valve whenever generator is not operating Ÿ DG950 generators use two stroke engines and oil must be pre mixed with...

Page 8: ...en Clean if fuel filter blocked Battery flat Electric start Charge replace battery 7 TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Ÿ Change engine oil after first month or after 20hrs operation and thereafter every 3 months or 50 hours of operation in both cases whichever is sooner AIR CLEANER Check the air cleaner every 3 months or after 50 hours operations whichever is the sooner Clean by blo...

Page 9: ...6 PROBLEM POSSIBLE CAUSE SOLUTION Check engine speed Reduce generator load Low Electrical output Low output voltage Excessive electrical load ...

Page 10: ...espect of any defect or failure of equipment supplied is limited to making good by replacement or repair at the Company s discretion defects which under proper use appear therein and arise solely from faulty design materials or workmanship within a specified period This period commences immediately after the equipment has been delivered to the customer and at its termination all liability ceases A...

Page 11: ......

Page 12: ...INS302G 02 20 ...