background image

3

Model

Motor

(kW)

Dimensions (mm)

Weight 

(kg)

L

W

0.5

0.3

4.5

3

4

3

1

330

285

205

183

280

253

7

6

P2

Current

(A)

Inlet/

Outlet

(”)

H

DSmart500

DSmart300

DSmart750

0.75

5.5

5.2

390

195

290

9

DSmart1500

1.5

7

13.1

511

215

382

24

2

Max

Inlet/Outlet

Pressure (Bar)

Inlet

W

L

H

Outlet

DSmart300/500

Dsmart750

Outlet

Inlet

H

L

Outlet

Inlet

H

DSmart1500

W

PUMP DATA

2.  SYMBOLS AND WARNINGS

WARNING

WARNING

The power supply cable should never be used to carry or shift the 
pump. If damaged, it must be replaced with a cable of similar 
specication.

Before  commencing  installation  ensure  equipment  is  well 
protected and the power supply has been switched off. 

WARNING

The power cable should be provided with short circuit protection 
(MCB)  to  guard  against  high  frequency  currents  faults.  Ensure 
that the earthing complies with the required local standards. 

WARNING

The pump is supplied with grounding wire. To reduce the risk of 
electric shock, ensure that the pump is properly grounded. 

WARNING

It is not recommended to use RCD (Residual Current Device) with 
variable speed drives/motors. However, if mandatory, use Type B 
because of the nature of the constant DC leakage current.

The electrical connections should be carried out in accordance 
with local regulations. Ensure that the values indicated on the 
nameplate match with the supply voltage and frequency. 

WARNING

Summary of Contents for DSmart300

Page 1: ...DSmart Smart Water Boosting System Installation Operating Manual DSmart300 500 DSmart750 DSmart1500...

Page 2: ...PUMP SPECIFICATIONS 1 1 2 SYMBOLS WARNINGS 3 INSTALLATION 3 4 OPERATION 4 10 MAINTENANCE 5 12 INDEX Davis Shirtliff Ltd 2023 Contents herein are not warranted TROUBLE SHOOTING 6 14 WARRANTY 7 17...

Page 3: ...and any queries should be referred to the equipment supplier 35 3 FLOW RATE m hr 10 20 30 0 4 8 16 20 12 10 20 30 40 60 0 1 2 3 4 5 50 6 5 15 25 35 45 55 3 FLOW RATE m hr 10 20 30 5 15 25 PUMP HEAD m...

Page 4: ...luding standard inlet and outlet connectors and inbuilt non return valve High Low temperature protection and leakage warning Integrated pressure tank for dry running and anti cycling protection Parall...

Page 5: ...ipment is well protected and the power supply has been switched off WARNING The power cable should be provided with short circuit protection MCB to guard against high frequency currents faults Ensure...

Page 6: ...Glade Impeller Guide Glade Impeller Seal Holder Waterproof Gland Pump Support Rotor Bearing Motor Aluminium Nylon 66 304 Nylon Nylon 66 PPO PPO PPO PPO PPO Aluminium EPDM 304 CR15 No 16 17 18 19 20 2...

Page 7: ...PC PBT PPO GF30 No 14 15 16 17 18 19 20 21 22 23 24 25 26 Fan Cover Fan Capacitor Box Gland Controller Stator Overhead Tank Transducer Sensor Bracket Bottom Bracket Check Valve Pump Body Check Valve P...

Page 8: ...r Gearing Hull Seal Holder Pump Support 45 Nickel plating HPb59 1 06Cr19Ni10 NBR No 14 15 16 17 18 19 20 21 22 23 24 25 26 Rotor Motor Fan Fan Cover Bearing Controller Panel Gland Hull Overhead Tank M...

Page 9: ...a stable level base by utilizing screws inserted through the openings in the base plate Fig 3 Fig 2 Fig 1 WARNING For emergencies and maintenance the pump must be easily accessible WARNING The pumps...

Page 10: ...ensure the foot valve is not exposed above the water surface When the length of the water inlet pipe is more than 10m or the lifting height of the water is more than 4m the diameter of the water inle...

Page 11: ...9 Installation Examples Higher Floor Tank Tank Tank Roof Higher Floor Higher Floor Foot Valve Well Ground Tap Water Roof Lower Floor Ground Higher Floor Lower Floor...

Page 12: ...seconds after main power is introduced Close the tap once water flows Open the highest tap point in the installation such as a shower Use the buttons to adjust the pressure set point to the required p...

Page 13: ...take 3 seconds switch light on Press the power button to stop the pump switch light off Press and hold power button for 10 seconds to switch between pressure mode and speed mode 1 2 3 4 5 6 Troublesho...

Page 14: ...main off for 5 minutes The pump will then run two times the same sequence If the water shortage still remains it will stop operation for 6 hours before attempting to start again Maintenance in Operati...

Page 15: ...e motor severally to prevent the graphite ring from breaking and damage due to sudden starting The seal leakage tolerance is 3 drops min otherwise it should be repaired When repairing and assembling t...

Page 16: ...or or driver board is damaged and may need to be replaced E6 Loss of phase Check whether the motor cable is connected measure the resistance of the motor wire and check if there is any discontinuity E...

Page 17: ...with no water being discharged Clear blockage Pump is not primed Remove the drain plug and ensure pump is filled with water Pump drawing in air Check inlet pipes if there is a leakage Pump inlet press...

Page 18: ...s noisy Bearing damaged Repair or replace else contact Dayliff retailer Impeller damaged Inlet pipe is too small Check inlet pipe size Pump leaks Mechanical seal worn out Replace mechanical seal Pipes...

Page 19: ...of careless handling lack of maintenance faulty installation incompetence on the part of the equipment user Acts of God or any other cause beyond the Distributors reasonable control Also any repair o...