3
Model
Motor
(kW)
Dimensions (mm)
Weight
(kg)
L
W
0.5
0.3
4.5
3
4
3
1
330
285
205
183
280
253
7
6
P2
Current
(A)
Inlet/
Outlet
(”)
H
DSmart500
DSmart300
DSmart750
0.75
5.5
5.2
390
195
290
9
DSmart1500
1.5
7
13.1
511
215
382
24
2
Max
Inlet/Outlet
Pressure (Bar)
Inlet
W
L
H
Outlet
DSmart300/500
Dsmart750
Outlet
Inlet
H
L
Outlet
Inlet
H
DSmart1500
W
PUMP DATA
2. SYMBOLS AND WARNINGS
WARNING
WARNING
The power supply cable should never be used to carry or shift the
pump. If damaged, it must be replaced with a cable of similar
specication.
Before commencing installation ensure equipment is well
protected and the power supply has been switched off.
WARNING
The power cable should be provided with short circuit protection
(MCB) to guard against high frequency currents faults. Ensure
that the earthing complies with the required local standards.
WARNING
The pump is supplied with grounding wire. To reduce the risk of
electric shock, ensure that the pump is properly grounded.
WARNING
It is not recommended to use RCD (Residual Current Device) with
variable speed drives/motors. However, if mandatory, use Type B
because of the nature of the constant DC leakage current.
The electrical connections should be carried out in accordance
with local regulations. Ensure that the values indicated on the
nameplate match with the supply voltage and frequency.
WARNING