1. SPECIFICATIONS

Ultrasun UFD Flatplate solar hot water systems are established and effective heaters that 
provide excellent performance, good value and guaranteed long life. They are of Open 
Loop thermosyphon type with the water flow circulating through the collectors and being 
stored in the tank ready for use. Features include:-

 

•  Heavy duty tank that features a resin insulated totally weather proof GRP casing, a 

heavy duty galvanised cylinder internally piped to optimise hot water availability and 
magnesium sacrificial anode  for cathodic  corrosion  protection.  An  in-built 3kW 
electric water heater with thermostat is included as standard. 

 

•  Solar collectors that incorporate full area copper absorption plates ultrasonically 

welded  to  copper  circulation  tubes,  high  specification  insulation  and  tempered 
security glass to provide energy absorption of up to 95%.

  •  Low thermal conductivity high specification plastic collector tank connection piping 

with silver foil coated polystyrene insulation jackets. 

  •  Connection piping that includes an incoming non-return valve, a thermosyphon 

0

diverter valve controlling max water temperature to 60 C to avoid scalding on hot 
days, pressure release valve and drain cock. All fittings are provided from the inlet to 
the outlet for simple installation.

  •  Galvanised mounting frame.

Ultrasun UFD Flatplate solar water systems are available in various tank sizes and collector 
configurations to suit domestic and small scale institutional applications. They are effective 
and  robust  products  designed  for  many  years  of  trouble  free  operation  with  a  5  year 
guarantee to demonstrate the product quality. With the benefits of progressive design and 
high quality components they are the ideal solution for all solar water heating applications.

DESIGN FEATURES

Congratulations on selecting a Ultrasun UFD Flatplate Solar Hot Water 
System.  They  are  manufactured  to  the  highest  standards  and  if 
installed and operated correctly will give many years of efcient and 
trouble  free  service.  Careful  reading  of  this  Installation  Manual  is 
therefore important, though should there be any queries they should 
be referred to the equipment supplier.

Magnesium anode bar 
for corrosion protection 

Elegant long life GRP resin
insulated tank casing

Copper riser pipes and
manifold tubes

High transmittance 
tempered security glass 
cover

Rigid galvanised rectangular
section mounting frame for 
ease of installation

Screwed brass outlets

3kW electric booster 
heater

High pressure galvanised 
steel storage tank with internal
piping designed to optimise
hot water availability

Pure aluminium powder 
coated frame

Outlet piped from hottest area 
of tank with air bleed and
pressure release valve fitted

Multi layer internal
insulation including injected
polyurethane base coated
with mineral wool and covered
with aluminium foil

Full area black coated copper
absorber sheet ultrasonically
welded to the risers to 
maximise heat transfer

Summary of Contents for ULTRASUN UFD

Page 1: ...Installation Operating Manual ULTRASUN UFD Flatplate Solar Systems...

Page 2: ......

Page 3: ...INDEX Davis Shirtliff Ltd 2020 Contents herein are not warranted 5 INSTALLATION 6 6 SYSTEM COMMISSIONING 7 7 USAGE 7 8 MAINTENANCE 7 9 TROUBLE SHOOTING 8 10 TERMS OF WARRANTY 10 3 WARNINGS SYMBOLS 3...

Page 4: ...e in various tank sizes and collector configurations to suit domestic and small scale institutional applications They are effective and robust products designed for many years of trouble free operatio...

Page 5: ...0 1 X FCP2 4 UFD320DS 3 0 1 7 18 48 12 A B C D E Full Weight kg Empty Weight kg Dimensions mm F 800 1920 2620 2780 700 253 93 600 800 1890 2590 2780 700 270 110 600 800 1890 2590 2780 700 355 135 600...

Page 6: ...ation It is necessary to do so in a safe and workman like manner taking due care of any aspects of the works that could result in injuries to person in or about the building as well as workers passers...

Page 7: ...lectors should be covered while doing so Steam can escape from the expansion relief valve of the solar pump unit if the system is shut down To avoid injuries an expansion relief valve must be connecte...

Page 8: ...irradiation and also assists in the thermosyphon process Heater units should never be laid flat l Avoid any shade especially between 10am and 4pm Shade hugely reduces system efficiency Preferably sola...

Page 9: ...a gravity system or pressurised supply Pressurised systems are preferable as they give higher line pressures up to a maximum of 3 5 Bar Note that in the case of pressurised supply hot and cold lines m...

Page 10: ...nated in the collection capillaries Once primed it is vital to ensure that the system is properly sealed as fluid loss will render the system ineffective The system must therefore be thoroughly checke...

Page 11: ...ow 9 TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Insufficient hot water High hot water usage at night Rotation use or replace with a larger system Prevailing weather conditions Incorporate compli...

Page 12: ...Lift valve hand lever and reset valve High mains pressure Use a pressure tank to regulate and reduce pressure levels Pressure is below specification settings Replace the valve if discharge continues...

Page 13: ...udes defects caused by fair wear and tear the effects of careless handling lack of maintenance faulty installation incompetence on the part of the equipment user Acts of God or any other cause beyond...

Page 14: ......

Page 15: ......

Page 16: ...INS455A 07 20...