18
PRE-OPERATION INSPECTION AND MAINTENANCE
REV LIMITER SELECTION: FDX, FLX
ANIMA FDX/FLX ENGINE comes with rev limiter selectable CDI unit.
To change the rev limiter, it needs to change the connection of the wires that come out of the
CDI unit.
WIRE CONNECTION TABLE
Color of Wire
BLUE
GREEN
BLACK/
YELLOW
Rev Limiter (1)
-11,500rpm
Rev Limiter (2)
-12,200rpm
Rev Limiter (3)
-12,900rpm
Example (How to select)
* To select Rev Limiter (3)-12,900rpm, connect Blue and Green wires.
Summary of Contents for ANIMA F Series
Page 5: ...4 PART NAMES...
Page 21: ...20 ELECTRICAL DIAGRAM for FDX...
Page 22: ...21 ELECTRICAL DIAGRAM for FLX F ANIMA F model is non selectable CDI...