background image

Daytona Users Instructions 

                                                                                                     200551_01 

Page 1 of 4 

 

 

Daytona Electric Fire 

User’s Instructions for Fan Heater Model with Thermostat control. 

These instructions should be read carefully and retained for future reference.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
Fire Installation  

Unpack the heater carefully and retain all packaging for future use. Ensure that all packing items are moved and read any warning labels 
carefully (see Maintenance Section). 
 
If the fire is to be installed in front of an existing chimney opening and there is any risk of chimney debris falling down onto the fire it 
is recommended that  before  installation the flue or opening  is  sealed off  with non-combustible  non-fibrous  insulation  materials.  Do 
not install into an existing fireplace that is prone to dampness. Should it be 
necessary  to  cap  and  seal  the  chimney  to  prevent  personal  injury,  a 
professional should be hired to do the work.  

The appliance must be positioned so that plug is accessible. Only when you 
are certain that you have completed the installation  should you plug in  and 
switch on at the wall socket. 

Preparation for Use. 

Check that the supply voltage details on your fuel effect fire are in accordance with 
your  electricity supply.  Your fire is fitted  with  a  plug incorporating  a  13 Amp fuse. 
In the event of replacing the fuse in the plug supplied, a 13 Amp fuse approved by 
ASTA to BS 1362  must  be used.   Before switching  on, please read the following 
operation instructions:  

Safety Thermal Cut-out

 

The  appliance  is  fitted  with  an  Electric  Safety  Control  (E.S.C).  This  is  a  safety 
device, which switches off the fire if for any reason, the appliance overheats. The 
E.S. Control will only be re-set after the appliance has cooled down, in order to re-
set the E.S. Control proceed as follows:  

 

Switch off the appliance and leave for approximately 5-10 minutes. 

 

Switch on the appliance and E.S. Control should normally re-set.  Ensure that 
the appliance is functioning correctly.  

Important Notes 

 

For the fitting of the fire in the surround please see the instructions supplied with the surround 

 

These Instructions should be read carefully and retained for the future reference. 

 

This heater must not be located immediately below a fixed socket outlet. 

 

Do not use the heater in the immediate surrounds of a bath, a shower, or a swimming pool. 

 

Do not cover this heater, or obstruct the air inlet or outlet, otherwise there is a risk of overheating. 

 

Do not stand the fire on the carpet – stand on a firm surface which projects 250 mm (10 inches) beyond the front of the fire and is free 
of dust and lint.  

 

Certain carpets can be  discoloured  by heat.  Ensure that furniture, curtains  and  other combustible  materials  are positioned no closer 
that 1m from the front of the fire. 

 

On heaters where the supply cord passes through a slot in the side of the casing, alternative positions are provided in the other side. 

 

This heater must be placed against a vertical surface i.e. back panel against a fireplace. 

 

Under no circumstances should the heater be used as a free standing appliance. 

 

During normal operation this appliance will emit noise from the internal fan unit.  

 

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or 
lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a 
person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

 

Warning:  This appliance must be earthed. 

The wires in the mains lead connected to this appliance are coloured in accordance with the following code: 

GREEN and YELLOW 

 

Earth 

BLUE 

 

 

 

Neutral 

Brown 

 

 

 

Live 

As the colour of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your 
plug, proceed as follows: 

 

The wire which is coloured Green and Yellow must be connected to the terminal in the plug which is marked with the letter E or by the 

earth symbol 

 or coloured Green or Green and Yellow. 

 

The wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Black. 

 

The wire which is coloured Brown must be connected to the terminal which is marked with letter L or coloured Red. 

Summary of Contents for bemodern

Page 1: ...h the surround These Instructions should be read carefully and retained for the future reference This heater must not be located immediately below a fixed socket outlet Do not use the heater in the immediate surrounds of a bath a shower or a swimming pool Do not cover this heater or obstruct the air inlet or outlet otherwise there is a risk of overheating Do not stand the fire on the carpet stand ...

Page 2: ...a vertical surface i e back panel against a fireplace and fixed in place using the brackets provided Wall back panel preparation Carefully mark out the holes positions drill and plug wall as shown in figure3 Fit two No 8x25 long pan head screws leaving approximately 2mm between the wall panel and the screw head see figure2 Fig3 Fig2 Fitting brackets to appliance Loosen but do not remove the two sc...

Page 3: ...ce and hence affect the performance We recommend that you clean around the fan grille housing at regular intervals This can be done using standard vacuum cleaner and suitable attachment Please note if the supply cord on this appliance is damaged it must be replaced by the manufacturer Authorised Service Agent or a qualified person to avoid hazard Note To prevent scratching of plastic and the front...

Page 4: ...ase must be retained by the Purchaser 3 The twelve month Guarantee does not apply to a Damage or inferior workmanship practices whilst the Product is being installed b Damage caused by mis use of the Product or where normal standards of care and use have not been complied with c Damage through a malfunction or an inadequately installed electric fire d Damage or defects due to mis use accident or u...

Reviews: