DAX66 INSTALLATION — 12V TRIGGERS
Using the DAX66 12VDC Trigger Inputs and Outputs
The DAX66 provides six 12Vdc trigger outputs which correspond to the six DAX66 zones. When a zone is powered ON by the DAX66
keypad, the corresponding zone sends 12Vdc to the trigger output jack. When the zone is powered OFF, 12Vdc is disconnected from the
trigger output. The triggers can be used to automatically switch peripheral equipment ON/OFF. The DAX66 also provides a master control
12Vdc trigger output that sends 12Vdc to the CONTROL OUT jack when any zone is powered ON and disconnects the 12Vdc when all
zones are powered off.
DAX66 Trigger outputs:
ZONES 1 ~ 6:
Zone ON; 12Vdc applied to the TRIGGER OUTPUT, Zone OFF; 12Vdc
removed from the TRIGGER OUTPUT.
CONTROL:
Any zone ON; 12Vdc applied to the CONTROL OUT, All zones OFF; 12Vdc
removed from the CONTROL OUT
DAX66 Trigger Inputs:
PA- IN:
Apply
12Vdc for input #1 override on all six zones.
MUTE – IN:
Apply 12Vdc to mute all zones.
WIRING:
3.5mm Mono
Plug: Tip Positive.
External Amplifier Control
To External
Amplifier
12VDC Trigger In
Motorized Projection Screen
To Projection
Screen 12 Vdc
Trigger In
!
daytonaudio.com
info@daytonaudio.com