background image

DAX66 SPECIFICATIONS & WARRANTY 

Specifications are subject to change from time to time 

without notice.

 

Contact Information:

Dayton Audio 

705 Pleasant Valley Drive 

Springboro, OH 45406 

PH: 937-743-8248 

E-Mail: 

info@daytonaudio.com

 

Web: 

www.daytonaudio.com

 

Warranty

 

This Dayton Audio® product is warranted free from defects 

in material and workmanship for a period of five years from 

date of purchase. Product registration is not required; 

however keep the original invoice as proof of purchase. 

Warranty does not apply to misuse, abuse, neglect, 

accident, improper use, etc. 

To process a return or have your product replaced under 

warranty, please contact your Dayton Audio reseller to  

to obtain an

 

RA #. Pack merchandise carefully to avoid 

further damage and complete the Return Form on the bottom

of the invoice. Record customer and RA numbers on the 

outside of the box. Ship merchandise back to your Dayton 

Audio reseller prepaid. 

RMS Power @ 8 ohms 

25 watts x 12 

RMS Power @ 4 ohms 

50 watts x 12 

RMS Power @ 8 ohms Bridge 

Mode 

100 watts  x  6 

S/N Ratio 

>85dB  A Weighted 

THD 

<0.1% 

Frequency Response 

20 ~ 20,000 Hz 

Input Impedance 

>47K ohms 

Input Sensitivity 

250mv 

Amplifier Protection 

Overload, Short Circuit & Thermal 

Trigger Systems ON Voltage 

DC + 12V 

Trigger External Mute Voltage 

DC + 12V 

Infrared Frequency Band 

38kHz 

Input Connectors 

!

3.5mm stereo, RCA, Toslink 

Output Connectors 

!

Terminal Block, RCA 

Power Supply (switchable) 

AC115V/60Hz, 230V/50Hz 

Dimensions 

16.9" (W) x 3.5" (H) x 16.4" (D) 

Weight 

24.25 lbs. 

Warranty 

5 Years 

!

daytonaudio.com

info@daytonaudio.com

© Dayton Audio

®

   Last Revised: 4/20/2015

Summary of Contents for DAX66

Page 1: ...6 SOURCE6 ZONE DISTRIBUTED AUDIO SYSTEM Model DAX66 UserManual...

Page 2: ...nience receptacles and the point where they exit from the unit Only use attachments accessories specified by the manufacturer Unplug this unit during lightning storms or when unused for long periods o...

Page 3: ...ith 4 8 ohm speakers in stereo mode 8 ohm speakers in bridged mono mode and provides a generous level of output power Please read and retain this manual to get the most from your Dayton Audio DAX66 6...

Page 4: ...PANSION IN OUT Connect up to 3 systems MODE switch BRIDGE STEREO Four stereo RCA INPUTS 12Vdc PA trigger IN KEYPADS Input connects to keypad hub 12VDC TRIGGER OUTPUTS activate external devices AC Inpu...

Page 5: ...keypad is designed for ease of use with a maximum ability to control sound Soft touch backlit buttons and a backlit LED display provide convenient control of the zone ON OFF source 1 6 selection volu...

Page 6: ...o in the zone Once the MUTE function is activated the keypad s LED display will flash indicating the mute status Press the MUTE button to continue playing music or press the keypad volume up or down b...

Page 7: ...ypads to the master controller amplifier we recommend Cat5e to connect keypads 5 The DAX66 uses a keypad hub all keypads will connect to the hub Install the keypad hub close to the master controller a...

Page 8: ...inches Don t be concerned that too much insulation has been removed since the wire will be hidden in the wall behind the keypad Remove approximately 1 4 of insulation from the conductors and insert i...

Page 9: ...r connect the Left Right channels of the amplifier together or combine the negative channels of the amplifier Improper speaker installation can damage the amplifiers and void the warranty If you are u...

Page 10: ...peaker load of 8 ohms Remove approximately 5 inches from the cable jacket strip 1 4 of insulation from the speaker wire and twist the copper strands Insert the speaker wires into the connector per the...

Page 11: ...or multiple zones The DAX66 can be used as the master controller in large commercial audio systems with constant voltage 25 70V amplifiers connected to the PRE AMP outputs The PRE AMP output levels ar...

Page 12: ...ip positive source 1 will be broadcast to all zones If there is no DC voltage is applied to the PA IN jack source 1 will operate like normal Infrared Emitter Outputs The DAX66 has an IR repeater syste...

Page 13: ...output that sends 12Vdc to the CONTROL OUT jack when any zone is powered ON and disconnects the 12Vdc when all zones are powered off DAX66 Trigger outputs ZONES 1 6 Zone ON 12Vdc applied to the TRIGG...

Page 14: ...UT terminal of the bottom unit and the other end of the ribbon cable to the EXPANSION INPUT terminal of the second and then third unit Set the MASTER SLAVE 1 SLAVE 2 switch of the bottom unit to MASTE...

Page 15: ...stands for control object code All All All Zone Zone Zone of of of Main Main Main unit unit unit 1 2 3 All All All Zone Zone Zone of of of Main Main Main unit unit unit 1 2 3 Zone1 Zone2 Zone3 of of...

Page 16: ...Zone2 Zone3 Zone4 Zone5 Zone6 of of of of of of Main Main Main Main Main Main unit unit unit unit unit unit 1 1 1 1 Key in keypad Key in Key in 19200 Key in 38400 Key in 57600 Key in 115200 Key in 23...

Page 17: ...eypad is turned 9600 CR change RS232 speed rate 19200 CR 38400 CR 57600 CR change change change RS232 RS232 RS232 speed speed speed rate rate rate to to to 19200 38400 57600 115200 230400 115200 CR ch...

Page 18: ...n an RA Pack merchandise carefully to avoid further damage and complete the Return Form on the bottom of the invoice Record customer and RA numbers on the outside of the box Ship merchandise back to y...

Reviews: