WARNING 

D

eath, serious injury, or fire hazard could result from improper connection of this instrument. Read and understand

 

this 

manual before connecting this instrument. Follow all installation and operating instructions while using this instrument. 

Connection of this instrument must be performed in compliance with the National Electrical Code (ANSI/NFPA 70-2014) of 
USA and any additional safety requirements applicable to your installation. 

Installation, operation, and maintenance of this instrument must be performed by qualified personnel only. The National 
Electrical Code defines a qualified person as “one who has demonstrated the skills and knowledge related to the construction 
and operation of the electrical equipment and installations, and who has received safety training on the hazards involved.” 

Qualified personnel who work on or near exposed energized electrical conductors must follow applicable safety related 
work practices and procedures including appropriate personal protective equipment in compliance with the Standard for 
Electrical Safety Requirements for Employee Workplaces (ANSI/NFPA 70E-2012) of USA and any additional workplace safety 
requirements applicable to your installation. 

ADVERTENCIA 

Una conexión incorrecta de este instrumento puede producir la muerte, lesiones graves y riesgo de incendio. Lea y entienda 
este manual antes de conectar. Observe todas las instrucciones de instalación y operación durante el uso de este 
instrumento. 

La conexión de este instrumento a un sistema eléctrico se debe realizar en conformidad con el Código Eléctrico Nacional 
(ANSI/NFPA 70-2014) de los E.E.U.U., además de cualquier otra norma de seguridad correspondiente a su 
establecimiento. 

La  instalación,  operación  y  mantenimiento  de  este  instrumento  debe  ser  realizada  por  personal  calificado  solamente.  El 
Código Eléctrico Nacional define a una persona calificada como "una que esté familiarizada con la construcción y operación del 
equipo y con los riesgos involucrados." 

El personal cualificado que trabaja encendido o acerca a los conductores eléctricos energizados expuestos debe seguir 
prácticas y procedimientos relacionados seguridad aplicable del trabajo incluyendo el equipo protector personal apropiado 
en conformidad con el estándar para los requisitos de seguridad eléctricos para los lugares de trabajo del empleado (ANSI/
NFPA 70E-2012) de los E.E.U.U. y cualquier requisito de seguridad adicional del lugar de trabajo aplicable a su instalación. 

AVERTISSEMENT 

Si l'instrument est mal connecté, la mort, des blessures graves, ou un danger d'incendie peuvent s'en suivre. Lisez 
attentivement ce manuel avant de connecter l'instrument. Lorsque vous utilisez l'instrument, suivez toutes les 
instructions d'installation et de service. 

Cet instrument doit être connecté conformément au National Electrical Code (ANSI/NFPA 70-2014) des Etats-Unis et à 
toutes les exigences de sécurité applicables à votre installation. 

Cet  instrument  doit  être  installé,  utilisé  et  entretenu  uniquement  par  un  personnel  qualifié.  Selon  le  National  Electrical 
Code, une personne est qualifiée si "elle connaît bien la construction et l'utilisation de l'équipement, ainsi que les dangers 
que cela implique". 

Le personnel qualifié qui travaillent dessus ou s'approchent des conducteurs électriques activés exposés doit suivre des 
pratiques en matière et des procédures reliées par sûreté applicable de travail comprenant le matériel de protection 
personnel approprié conformément à la norme pour des conditions de sûreté électriques pour les lieux de travail des 
employés  (ANSI/NFPA 70E-2012) des Etats-Unis et toutes les conditions de sûreté additionnelles de lieu de travail 
applicables à votre installation. 

Summary of Contents for IL78A

Page 1: ...ment which aligns the transducer s return output signal to the conditioner s demodulator When the demodulator is aligned properly through calibration maximum amplitude and linearity are achieved The Model IL78A s is calibrated by means of a two point dead weight or shunt calibration technique which are outlined in section three The user can utilize the shunt calibration method by adding the correc...

Page 2: ...ste instrumento debe ser realizada por personal calificado solamente El Código Eléctrico Nacional define a una persona calificada como una que esté familiarizada con la construcción y operación del equipo y con los riesgos involucrados El personal cualificado que trabaja encendido o acerca a los conductores eléctricos energizados expuestos debe seguir prácticas y procedimientos relacionados seguri...

Page 3: ...rd für elektrische Sicherheitsauflagen für Angestellt Arbeitsplätze ANSI NFPA 70E 2012 der Vereinigten Staaten und alle zusätzlichen Arbeitsplatzsicherheitsauflagen folgen die auf Ihre Installation anwendbar sind Safety Precautions The following safety precautions must be followed whenever any type of voltage or current connection is being made to the instrument o Before connecting to electric cir...

Page 4: ...el material aislante no tenga rajaduras Reemplace de inmediato cualquier parte defectuosa Mesures de Sécurité Les mesures de sécurité suivantes doivent être prises chaque fois qu un type de connexion quelconque est effectué sur l instrument ο Ouvrir les disjoncteurs correspondants lors d une connexion à des circuits électriques ou à des équipement de génération d impulsions NE PAS effectuer de con...

Page 5: ...henden Schaltung hergestellt werden ο Tragen Sie Schutzbrillen und Isolierhandschuhe wenn Sie Anschlüsse an den Stromkreisen vornehmen ο Hände Schuhe und Fußboden müssen trocken sein wenn Sie Anschlüsse an den Stromkreisen durchführen ο Stellen Sie sicher daß das Gerät AUSgeschaltet ist bevor Sie an der rückwärtigen Konsole Meßfühler anschließen ο Prüfen Sie vor jedem Gebrauch alle Kabel auf Bruch...

Page 6: ...ale Output 10 Hz To 1 of final value 0 08 sec 0 008 sec 100 Hz 0 0011 sec 650 Hz To 0 1 of final value 0 095 sec 0 0095 sec 100 Hz 0 0016 sec 650 Hz To 0 02 of final value 0 10 sec 0 01 sec 100 Hz 0 0014 sec 650 Hz coupled 120 to 10 k ohm Analog Ouput selectable 0 to 5 0 to 10 Vdc 4 12 20 or 4 20mA 20 over range voltage only Power Supply 11 28 Vdc regulated 100 mA max Operating Temperature 10 to 7...

Page 7: ...Function 1 2 3 4 5 6 7 8 Analog Output SHP SHN Sync Analog Common Power Common 24 Vdc Shield Signal Output Shunt positive switch input Shunt negative swithc input Master Slave Sync I O Signal Output Power Supply Common 11 28 Vdc Input Power Earth ground 1 2 3 4 5 6 7 8 Excitation Sense Excitation Sense Signal Signal Cal Sense Shield Sensor Power Sensor Power Sense Sensor Power Sensor Power Sense S...

Page 8: ...ve and wired as shown with the SYC terminals connected and a separate Power Common wire If the units share a common power supply the Power com terminal should be connected at the modules Shunt Resistor Selection The IL78A has a Internal and External shunt selection jumper located between the two wiring connectors Below are the appropriate wiring and jumper selections depending on the application u...

Page 9: ...Fig 4 Remote Shunt Activation Connections TRANSDUCER CONNECTIONS IL78A 2 AC Strain Gage Conditioner Module IL78A ...

Page 10: ...ibration resistor for convenience in subsequent checking Install an external calibration resistor with one or an equivalent resistance value supplied by the transducer manufacturer to achieve a precisely known Equivalent Input allowing the instrument sensitivity to be adjusted correctly Move jumper from INT to the ETX terminals install resistor between Cal Sense and or Signal Determine the Equival...

Page 11: ...ad weight value greater than one half of full scale Adjust Coarse Span for a nominal corresponding output Adjust the PHASE control until a maximum output value is obtained Once set for your transducer this PHASE ADJUSTMENT step need not be repeated unless a change in cable length or transducer is required Unload the sensor and re Zero as needed e f If the calibration will utilized a known dead wei...

Page 12: ...n document The SYMMETRY control has approximately 7 authority full scale If dead weight calibration is not practical and the transducer calibration data is unknown the Equivalent Input value for the factory installed calibration resistor can be approximated as follows assuming that the mv v sensitivity rating of the transducer and the bridge resistance are known l m where X Equivalent Input of ful...

Page 13: ...ure 7 3 CALIBRATION cont Switch 1 Mode current I or voltage analog output Switch 2 Volts 5 or 10 Vdc when mode is voltage Switch 3 Current 4 12 20 or 4 20mA when mode is current Switch 4 Filter 650Hzor100Hzat3db for100Hzswitch5mustbesetdown Switch 5 Filter 10Hzor100Hzat3db for100Hzswitch4mustbesetdown Switch 6 Sync excitatonclocktoslavefromamastermoduleortobemaster Switch 7 Zero Adj extended 100 o...

Page 14: ...n of the loading or off zero reading c The inability to balance correctly where the instrument output readstotally off scale and the BALANCE controls have no authority can very likely be the result of a damaged or defective transducer or cable This possibility can be confirmed or eliminated by substituting a transducer and cable known to be in good condition or by simulating a balanced transducer ...

Page 15: ...Fig 4 Star Bridge AC Strain Gage Conditioner Module IL78A ...

Page 16: ...r workmanship or the refund of the purchase price to the Buyer Before returning a product or products for any reason the customer must call Daytronic Customer Support Services at ALL EQUIPMENT TO BE REPAIRED OR REPLACED UNDER WARRANTY MUST BE RETURNED TO THE FACTORY Once the customer has provided the necessary information and has been assigned a specific RMA the product s in question may be return...