18
TROUBLE SHOOTING
DAYVA PREMIERE OUTDOOR HEATER
CARE & CLEANING
Cleaning the Heater
Follow the Trouble Shooting Guide for CLEANING THE ORIFICE. This should be done at least once
a year, more if a problem occurs.
Open the Heater Access Plate, located opposite of the Controls and clean any debris from inside the
neck. Make sure to pay special attention to the valve and ignitor.
The Emitter Screen can be cleaned with products like Oven Cleaners.
Cleaning the exterior surfaces and hood
You can wash your heater just like a car. Use mild detergent and rinse with water.
Keeping your heater clean allows it to operate and provide years of service.
If a scratch occurs in a powder coated surface, quickly touch-up with an exterior acrylic based paint.
Touching up will lessen the possiblility of rusting in that area.
Dayva International, unfortunately does not supply touch-up paint.
About 1/8" spark gap between
Electrode and Thermocouple
PROBLEM 3
Ignitor not lighting pilot
CAUSE
Electrode not creating a sufficient enough spark to
ignite the gas
SOLUTION
CHECK SPARK GAP AND ELECTRODE
CONNECTIONS
1. Remove the hood and emitter by removing the (4)
screws that attach the emitter screen to the burner
plate.
2. Check the spark gap and adjust as illustrated.
3. Check all Electrode wire connections.