AW_DD650_manual_G04_150923.ai 19 2015/9/23 16:12:39
Parameter
Value
Description
GM MODE
ON/OFF
ON: The channel 10 will respond GM drum kit.
OFF: The channel 10 will respond local drum kit.
LOCAL CTRL
ON/OFF
Describe the connection state about pad signal and internal sequencer with internal
sound generator.
ON: The pads and internal sequencer are connected to the digital
drum’s internal
sound generator. Sounds are produced by the internal sound generator when the
pads are struck.
OFF: The pads and internal sequencer are disconnected from the digital
drum’s
internal sound generator. Striking the pads does not cause sound to be produced
by the internal sound generator.
L-R EXCHANG
ON/OFF
Exchange the left and right pad position.
R: Normal settings.
L: You can exchange the left and right pad position to satisfy the left-hand player.
AUTO POWER
30, 60 ,OFF
Factory settings, approximately 30 minutes.
30: Automatically turns the power off if no operation for approximately 30 minutes.
60: Automatically turns the power off if no operation for approximately 60 minutes.
OFF: The power will not power off automatically.
Utility Settings
1.
In the KIT menu, select the
“UTILITY” item.
2.
Press the [
∧
]/ [
∨
] button to select the utility parameters that you
want to edit.
C
M
Y
CM
MY
CY
CMY
K
3.
Use the [<] / [>] button or data dial to adjust the parameter value.
19