47
IA504R
Cod. 420120398 REV. 1.0
BRIDGE SETUP
70/100V SETUP
STEREO Setup
OUT 1
OUT 2
BRIDGE Setup
OUT 1
+ BRIDGE
OUT 1
OUT 3
OUT 2
OUT 4
+ BRIDGE
Default Bridge Input Configuration
Don't connect any
Output to Ground
Default Input Configuration
70/100V Setup
OUT 1
+ BRIDGE
OUT 1
OUT 3
OUT 2
OUT 4
+ BRIDGE
Don't connect any
Output to Ground
Default 70/100V Input Configuration
IN 4
IN 1
IN 2
IN 3
Minimum inpedance
8 omh
Don't connect any
Output to Ground
IN 4
IN 1
IN 2
IN 3
+ BRIDGE
OUT 1
OUT 3
OUT 2
OUT 4
+ BRIDGE
IN 4
IN 1
IN 2
IN 3
STEREO Setup
OUT 1
OUT 2
BRIDGE Setup
OUT 1
+ BRIDGE
OUT 1
OUT 3
OUT 2
OUT 4
+ BRIDGE
Default Bridge Input Configuration
Minimum inpedance
4 omh
Don't connect any
Output to Ground
70/100V Setup
OUT 1
+ BRIDGE
OUT 1
OUT 3
OUT 2
OUT 4
+ BRIDGE
Don't connect any
Output to Ground
Default 70/100V Input Configuration
IN 4
IN 1
IN 2
IN 3
Minimum inpedance
8 omh
Don't connect any
Output to Ground
IN 4
IN 1
IN 2
IN 3
+ BRIDGE
OUT 1
OUT 3
OUT 2
OUT 4
+ BRIDGE
IN 4
IN 1
IN 2
IN 3
CAUTION
!
•
Do not connect the outputs to ground.
NETWORK WIRING
RDNET
Data
In
Data
Out
RDNet
Data
In
Data
Out
Device 2
Data
In
Data
Out
Device 32
Data
In
Data
Out
Device 1
Data
In
Data
Out
Device 2
Data
In
Data
Out
Device 32
Device 1
RDNet
Control 2 | Control 8
Connecting and linking the control signal from
the RDNet interface.
Connecting one speaker in bridge mode. Load
the correct setup from the Setup => Output
section of AURORA NET. The impedance must be
8 Ohm or greater.
Connecting a speaker in 70/100V mode. Load the
correct setup from the Setup => Output section of
AURORA NET.