3
WARNING:
This product is part of a fall arrest or rescue system. These instructions must be provided to all
users and rescuers using this equipment. The user must read and understand these instructions before using
this equipment. The user must follow the manufacturer’s instructions for each component of the system.
Manufacturer’s instructions must be followed for proper use and maintenance of this equipment. Alterations or
misuse of this equipment, or failure to follow instructions, may result in serious injury or death.
IMPORTANT:
If you have questions on the use, care, or suitability of this equipment for your application,
contact Capital Safety.
IMPORTANT:
Before using this equipment, record the product identification information from the ID label into
the inspection and maintenance log of this manual.
IMPORTANT:
Systems are designed to be used with Jib Systems manufactured by Capital Safety only.
OSHA Models
CE Models
All connecting systems, (self retracting lifelines, winches and
energy absorbing lanyards) used with the Jib Mast and Base
system shall limit the average arresting forces to 4 kN (900
lbf).
All connecting systems, (self retracting lifelines, winches and
energy absorbing lanyards) used with the Jib Mast and Base
system shall limit the average arresting forces to 6 kN (1350
lbf).
IMPORTANT
:
System is only rated for one user.
IMPORTANT
:
System is only rated for one user.
8530483
8560026
8530564
SPECIFICATIONS:
General Construction
Welded Steel
Structural Material
A36 Steel
Finish
Zinc Plate per ASTM B633, Type 2
Hitch Pin Material
A36 Steel
Hitch Pin Finish
Zinc Plate
Training
: It is the responsibility of users of this equipment to understand these instructions and be trained
in correct installation, use, and maintenance of this equipment. Users must be aware of the consequences
of improper installation or use of this equipment. This instruction manual is not a substitute for a training
program. Training must be provided on a periodic basis to ensure user proficiency.
Description
: The Concrete Mounted Jib Base
(Figure 1)
is a anchor point for overhead applications. The Concrete
Mounted Jib Base is designed for use with a vertical mast being inserted into a concrete mounted base.
Purpose
: The Concrete Mounted Jib Base is designed for use as a component of a Personal Fall Arrest System
(PFAS). PFASs are used where free fall is possible before the fall is arrested and typically include: a Self
Retracting Lifeline (EN 360) or Energy Absorbing Lanyard (EN 355); connector (EN 362) to attach to the
anchor; and a Full Body Harness (EN 361).
INSTALLATION:
Step-1
: Mark anchor holes to be drilled per Figure 2 -
A
layout.
•
Drill 129mm (Ø5.06”) hole to a depth of 578mm (22.75”) into the existing concrete. (See Figure 2 -
B
.)
Model
Mounting Hardware Minimum Moment Load
Minimum Vertical Load
8530483
39,047 N*m (345,600 in*lbs)
16 kN (3,600 lbs)
8560026
29,286 N*m (259,200 in*lbs)
12 kN (2,700 lbs)
•
Remove debris from hole and inject epoxy into hole per manufacturer instructions. (See Figure 2 -
C
.)
NOTE:
Ensure that no epoxy ingresses into anchor opening during install. Capital Safety recommends using
Rock River® All Weather 400 Epoxy, (Part# 0269002, 9.3 oz tube) or equivalent to anchor base.
•
After the Concrete Anchors have cured over the appropriate time as specified by epoxy manufacturer,
continue on to Step 2.
Step - 2
: Fastening the Mounted Jib Base:
•
Make sure the Core Holes are free of any debris before inserting the Jib Base. (See Figure 3.)
•
Fasten the Jib Base to the existing concrete by tightening the concrete anchor bolts to their
recommended torque.