background image

Inspection

Verify that the 576Õs package contains the following:

¥ 576 Unit (according to Model number marked on package)
¥ AC Power Cord
¥ Operation Manual
¥ Registration Card
¥ Rack screws & washers

If any of these items are missing, contact dbx customer service at (801) 568-7660.

Warranty

This warranty is valid only for the original purchaser and only in the United States. We warrant dbx
products against defects in materials or workmanship for a period of two years from the date of orig-
inal purchase for use, and agree to repair or, at our option, replace any defective item, except exter-
nal power transformers, without charge for either parts or labor.

IMPORTANT: This warranty does not cover damage resulting from accident, misuse or abuse, lack
of reasonable care, the affixing of an attachment not provided with the product, loss of parts, or con-
necting the product to any but the specified receptacles. This warranty is void unless service or repairs
are performed by an authorized service center. No responsibility is assumed for any special, inciden-
tal or consequential damages. However, the limitation of any right or remedy shall not be effective
where such is prohibited or restricted by law.

Simply take or ship your dbx product prepaid to our service department. Be sure to include your sales
slip as proof of purchase date. (We will not repair transit damage under the no-charge terms of this
warranty.) dbx will pay return shipping.

NOTE: No other warranty, written or oral is authorized for dbx products.

This warranty gives you specific legal rights, and you may also have other rights which vary from
state to state. Some states do not allow the exclusion of limitations of incidental or consequential
damages or limitations on how long an implied warranty lasts, so the above exclusion and limitations
may not apply to you.

3

Summary of Contents for 576

Page 1: ...Vacuum Tube Preamplifier Compressor Owner s Manual Version 1 0...

Page 2: ...ire shall be connected directly to the unit s chassis WARNING If the ground is defeated certain fault conditions in the unit or in the system to which it is connected can result in full line voltage b...

Page 3: ...ble of Contents Introduction 2 Features 2 Inspection 3 Warranty 3 Connections 4 Preamp Controls 5 Compressor Controls 10 Rear Panel Preamp 14 Rear Panel Compressor 16 Specifications 17 Settings Page 2...

Page 4: ...limiting and the advanced dbx V1 VCA module that ensures high system performance Precision 1 resistors are used through out the audio path to ensure performance stability and low noise To ensure year...

Page 5: ...oduct loss of parts or con necting the product to any but the specified receptacles This warranty is void unless service or repairs are performed by an authorized service center No responsibility is a...

Page 6: ...and 1 4 TRS connectors on the inputs and outputs can be used for bal anced or unbalanced connections However the use of more than one connector at a time on the input pair could unbalance balanced lin...

Page 7: ...This control varies the gain of the mid frequency equalization the gain range is 15 to 15 dB The mid frequency filter is a bandpass configuration with variable frequency and switchable bandwidth NARR...

Page 8: ...moderate settings of the Drive and Level controls if a high degree of tube saturation is desired this result can be obtained by using higher settings of the Drive control in conjunction with lower se...

Page 9: ...featuring Intelligent Predictive Limiting Its function is to monitor the input signal and intelligently predict the amount of gain reduction needed to keep the output signal below the ceiling set by t...

Page 10: ...dBu a meter read ing of 0 VU corresponds to 4 dBu output When the rear switch is set to 10 dBV a meter reading of 0 VU corresponds to 10 dBV output DITHER switch This switch becomes active only when...

Page 11: ...luminates when the signal is below the level set by the Compressor Threshold control This indicates that the Compressor is not compressing and is operating in its linear region THRESHOLD control This...

Page 12: ...very fast attack setting will cause the 576 to act like a peak Limiter even though RMS average level detection circuitry is used Slower attack settings cause the 576 to act like an RMS or averaging d...

Page 13: ...ny signal routed through the Compressor When the Preamp and Compressor sections are connected in series a high Drive control setting can be used in conjunction with a high drive setting on the Preamp...

Page 14: ...kPlus limiting circuit DRIVE LEVEL switch This configures the meter to show the signal level at the input to the vacuum tube Note that high gain settings can result in excessive movement of the meter...

Page 15: ...mic requires phantom power ensure that the phantom power switch on the front panel is turned off before connecting your mic LINE INPUTS Both XLR and 1 4 TRS connectors are provided to allow balanced o...

Page 16: ...rect post preamp output that bypasses the EQ and main output stages of the 576 The Send is post preamp and the Return is pre EQ Both the Send and Return are balanced TRS jacks with 4 dBu nominal sensi...

Page 17: ...Bu 10 dBV switch SIDECHAIN SEND The Sidechain Send and Return allow external processing of the Compressor s detector signal The Sidechain Send is typically used to feed an external equalizer to produc...

Page 18: ...or 470k unbalanced with rear panel INST switch engaged Maximum Input Level 30 dBu or 22 dBu with rear panel INST switch engaged Outputs Connectors Male XLR Pin 2 hot and TRS 1 4 Type Servo balanced un...

Page 19: ...rogram dependent Typically 250 dB sec to 5 dB sec Auto Attack Time Program dependent Typically 15ms for 10 dB 5ms for 20 dB and 3ms for 30 dB Auto Release Time Program dependent Typically 125 dB sec r...

Page 20: ...Hz to 20 kHz Interchannel Crosstalk Typically 98 dB 20 Hz to 20 kHz POWER SUPPLY Operating Voltage Switchable between 100 120 230 and 240VAC 50 60 Hz Power Consumption 30 Watts max Fuse 100 120V 500mA...

Page 21: ...19 dbx 576 Settings Page Photocopy this page and mark the settings you use for your sessions Session Date Comments Session Date Comments...

Page 22: ...South Sandy Pkwy Sandy Utah 84070 Phone 801 568 7660 Fax 801 568 7662 Int l Fax 603 672 4246 Questions or comments E mail us at customer dbxpro com or visit our World Wide Web home page at www dbxpro...

Reviews: