- 19 -
E2
Over- heat protection
Temp Sensor short circuit
Replace inverter
Inverter fault
Fan fault
E3
Low-voltage protection
power voltage below 185V
Make sure the voltage in the right
range
power voltage normal
E4
Incline motor correction
failure or error
Incline motor correction failure
Re-check incline motor after power
on
Inverter connection loosed
Check the connection
Inverter broken
Change inverter and re-check it
Incline motor broken
Change the incline motor and
re-check
E5
Over-current protection
motor with over current
Lubricating oil to reduce the
resistance between running belt and
running board
IPM module short circuit
Replace inverter
E6
Lower
controller
and
inverter
communication
abnormality
Lower controller and inverter was
not connected well
Check the Lower controller and
inverter whether connected well
Lower controller fault
Replace lower controller
Inverter fault
Replace inverter
E7
Over- load protection
parameter setup error
Replace inverter
over-loading
reduce loading
E9
Incline signal error
Incline sensor not connect well
Check the connecting of incline
sensor
Incline motor fault
Change incline motor
Inverter fault
Change inverter