Security
51
Level 1:
Using any configuration method, configure Administrator
Access IP addresses. Enter the IP addresses that should have
the ability to change the EtherPoll configuration. If configuring
this remotely, insure that the workstation you are using is one of
the valid addresses.
Level 2:
Using telnet or direct connection configuration, selectively
enable or disable remote configuration via Telnet, via web
browser, and SNMP. This setting may not be performed from
the web configuration screen.
Level 3:
Configure Level 1 and Level 2 security as needed. Using the
telnet or direct connection configuration, enter up to three user
name and password pairs. If there is at least one user name in
this list, then a password prompt will be issued upon
establishing a telnet configuration session.
There may be up to 3 user names and passwords configured. If
no users are configured, password protection is disabled. User
names and passwords are limited to 8 characters each. There is
a six failed login attempt limit. After six failed attempts in a
row, the unit will lock out all logins for a period of about 10
minutes.
Each user name has an associated user ID or index. The
user with ID 1 is considered the master user. It has the