53
Chapter 6
Operation
This Chapter explains how to use the
EtherPoll, once it is installed and configured.
Normal Mode
•
All EtherPolls must be connected as described in Chapter
3. Configuration is complete, and serial port configurations
match the associated serial port device (Polling host or
RTU). LAN configuration is complete with appropriate IP
addressing.
•
Power up all EtherPolls and associated hardware.
•
Start the polling program on the polling host computer. It
should automatically poll each RTU connected to an
EtherPoll whose IP address was stored during
configuration of the host EtherPoll.
•
Pin 6 input must be HIGH or Forced ON for the unit to
send and receive packets. When pin 6 is LOW, the serial
interface turns OFF the pin 4 (DTR) and 7 (RTS) output
signals.