PROBLEMS CHECK LIST
If you have any other issues, please contact your supplier or distributor. Please do not attempt to
modify the heater in any way or form.
Thermocouple bad
Pilot will not light
Gas valve may be OFF
lank fuel empty
Turn the gas valve ON
Refill LPG tank
Clean or replace opening
Purge air from lines
Check all fittings
Insert battery
Clean dirty area
Tighten connections
Opening blocked
Air in supply system
Loose connection
Battery not fit in
Debris around pilot
Loose connections
Gas leak in line
Lack of fuel pressure
Anti tilt switch
loose/faulty
Pressure is low
Opening blocked
Control not on
Thermocouple bad
Pilot light assembly bent
Not in correct location
Pilot will not stay on
Burner will not light
Replace thermocouple
Check connections
Tank near empty.
Refill LPG tank.
Position properly and retry
Place pilot properly
Replace thermocouple
Turn valve to ON
Remove and clean
Tank near empty.
Refill LPG tank.
Reconnect/replace
anti tilt switch
PROBLEMS
PROBABLE CAUSES
SOLUTIONS