G R I D D L E T RO U B L E S H O OT I N G
W H A T T O D O :
U S E F U L N OT E S :
CHECK 1) the Electrical / Gas Supply as out-
lined in the General Instruction section.
2) Remove Griddle plate assembly (fas-
tened by 2 screws in the front and 1 screw in
the back, under the flue cover- Visually check
for igniter breakage. If igniter is broken,
remove / replace
3) Remove Valve Panel (see General
instructions and note removal of "Red" screw
behind control knob -
not on all units
)
4) 120 V supplied to Thermostat from
the terminal block ?(live= black) If not, trou-
bleshoot power supply lines, If YES,
5) Disconnect power, Remove wires off
T hermostat & check for continuity between
T hermostat terminals when Thermostat dial is
rotated to the ON. If there is no continuity
remove / replace Thermostat.
6) If Thermostat is OK, Remove the
wires from the Thermal Valve and check for
continuity between the two (2) terminals on the
face of the valve. If none, remove / replace.
7) If the Thermal Valve is OK, Remove
the wires from the Griddle Igniter and check
the igniter leads for continuity. If none, remove
/ replace igniter.
8) If the Igniter is OK, Check the
Neutral Return Wire for continuity to the neu-
tral (white) wire of the power supply cord.
1) Verify Gas supply to the unit. Turn
the Gas supply OFF. Loosen tubing supplying
gas from the manifold to the Thermal Valve at
the Thermal Valve. Quickly turn manual valve
On, then Off while an assistant listens closely
for the sound of flowing gas at the loosened
end of the connection. If gas is not flowing,
check the tubing for blockage.
P ROBLEM AREA:
Griddle will not
operate
Griddle still will not
operate, (Electrically
operational -
Steps 1-8 OK)
N OTE: Be careful
not to damage the
Capillary when
removing the Griddle
plate assembly
N OTE: -Ensure at
the supply source
that the live and neu-
tral wires are not
reversed ( If they are,
this would not be
covered under
warranty)
15