INSTALLATION INSTRUCTIONS
Remote blower electrical connection
●
●
Remove the cover from the remote blower, then remove the wiring box cover.
●
●
Pull the electrical wiring through the hole in the blower base and secure it
according to local codes using a suitable UL listed strain relief or conduit fitting
(not included).
●
●
Connect the N (neutral) wire to the white wire in the wiring box with twist-on
connector Fig.28.
●
●
Connect the L1 (live) wire to the black wire in the wiring box with twist-on
connector Fig.28.
●
●
Connect the green power supply ground wire to the green ground screw.
Attention – verify that the main filter, flap and wiring box cover are positioned
correctly with wiring clearance.
●
●
Replace the wiring box cover and screws taking care not to pinch the wiring
under the wiring box cover.
●
●
Reinstall the remote blower cover.
Gr
ound scr
ew
s
GREEN -YELLOW
WHITE
BLA
CK
Motor wiring
Twist-on connectors
Downdraft wiring
GND (
gr
ound)
N (neutr
al)
L1 (liv
e)
Fig.28