Unit 4: Configuration
SATO MB200 Operator Manual
PN 9001126A
Page 4-2
DIP SWITCH COMPLEX DSW1
The following tables provide guidance on the enabling/disabling of various functions and
features. This chapter deals solely with dip switch complex DSW1.
FACTORY DEFAULTS
DSW 1-1
DSW 1-2
DSW 1-3
DSW 1-4
DSW 1-5
DSW 1-6
DSW 1-7
DSW 1-8
IF Specific
IF Specific
IF Specific
On
On
Off
Off
Off
INTERFACE CONFIGURATION
DSW 1-1
DSW 1-2
DSW 1-3
OPERATIONAL MODE
Off
Off
Off
RS-232C
On
Off
Off
TLL
Off
On
Off
IrDA
On
On
Off
Bluetooth (mode 1 using PIN code)
Off
Off
On
RS232C, IrDA
On
Off
On
TTL, IrDA
Off
On
On
Bluetooth (mode 2 no authentification)
On
On
On
Wireless LAN (802.11B)
AUTOFEED & HEAD CHECK CONFIGURATION
DSW 1-4
Off:
Manual Feed or Factory Offset /
On:
Auto Feed or Print Darkness adjustment
DSW 1-5
Head Check
- Off: Disabled / On: Enabled
MODE CONFIGURATION
DSW 1-6
DSW 1-7
DSW 1-8
OPERATIONAL MODE
Off
Off
Off
Factory Clear Mode w/o counter clear
On
Off
Off
Factory Clear Mode w/ head counter clear
Off
On
Off
Factory Clear Mode w/ head counter & factory counter clear
On
On
Off
Reserved
Off
Off
On
Dispenser Operation
On
Off
On
Hex Dump Mode
Off
On
On
Font Download
On
On
On
Program Download