Unit 4: Configuration
SATO MB200 Operator Manual
PN 9001126A
Page 4-12
FACTORY CLEAR MODE
Figure 5-10 provides the specific sequence of events required by the operator, the printer, and
the printer’s software for factory clear mode to be activated.
Figure 4-10, Factory Clear Mode
POWER
DSW1-6 = Reset
DSW1-7 = Reset
DSW1-8 = Reset
STATUS LED
Illuminates green
Test Printing of
Labels
Factory Clear Mode
PRINT + FEED + POWER
HEAD & FACTORY COUNTER CLEAR
DSW1-6 = OFF
DSW1-7 = ON
DSW1-8 = OFF
Open Cover
Press FEED key
STATUS LED
blinks red
STATUS LED
blinks green
FEED
Pause/Print/
Exit
STATUS LED
blinks green
Stops printing
labels
NO COUNTER CLEAR
DSW1-6 = OFF
DSW1-7 = OFF
DSW1-8 = OFF
Open Cover
HEAD COUNTER CLEAR
DSW1-6 = ON
DSW1-7 = OFF
DSW1-8 = OFF
Open Cover
Which Factory
Clear option
Close Cover